Difference between revisions of "Configuring Input Actions"

From exigoWiki
Jump to navigation Jump to search
(Common Parameters for Input Actions)
Line 52: Line 52:
  
 
== Common Parameters for Input Actions ==
 
== Common Parameters for Input Actions ==
 +
All Input Actions have some or all of the following parameters:
 +
'''<u>Destination</u>''' <br>
 +
The zone(s) that will be included in the broadcast. This may be left blank if access panel keys are used for zone selection.
 +
 +
'''<u>Repetitions</u>''' <br>
 +
Set the number of times the input action should be repeated.
 +
* Check the Loop box to make the repetition go in a loop
 +
 +
'''<u>Priority</u>''' <br>
 +
The priority of the broadcast.
 +
* Check the Replace box to make this broadcast replace other broadcasts with the same Priority.
 +
This is usually used for Programs. If the box is not checked, other broadcasts with the same priority will be regarded as busy. <br>
 +
Events with higher priority will get the zones for the broadcast, while events with lower priority will be queued by default. The lower the number, the higher the priority.
 +
 +
'''<u>Chime</u>''' <br>
 +
Select the chime that will sound before the audio broadcast.
  
 
[[Category:Input Actions]]
 
[[Category:Input Actions]]

Revision as of 12:14, 3 May 2018

Inputs are configured by defining one or more actions to be triggered on an input event. The various input functions available are listed below.

To display the available input actions:

  • Click Components at the lower-left of the window.
  • Click Input Actions

Available input actions are:

Configuration

Input actions can be assigned to either a key or a control input depending on system requirements.
These can be configured by dragging-and-dropping the different functions to either Control Inputs on Amplifiers or Programmable Keys on Access Panels, e.g.:

  • Drag-and-drop Input Actions to Access Panel > Programmable Keys > p1-px
  • Click Done.
  • press_action will be automatically configured to Start the activity
  • release_action will be automatically configured to Stop the activity

Activation
Start: This will start the broadcast in the selected zone/s and run for the number of repetitions configured or until it is stopped.
Stop: This will stop the selected broadcast if it has a higher priority than the active broadcast in the selected zone.
Toggle: This works as a start/stop function. If the broadcast is not active in the selected zone, it will work as a start function. If the selected broadcast is active in the zone, it will work as a stop function.
or

  • Drag-and-drop Input Actions to Amplifier > Control Inputs > CI_1-CI_6
  • Click Done
  • on_action will be automatically configured to Start the activity
  • off_action will be automatically configured to Stop the activity
Observe.PNG Programmable Keys press_action/release_action and Control Inputs on_action/off_action have to be individually configured for Input Actions: Activity Indicator, Backup Request, Clear Activity, System Status, Zone Selection.

Common Parameters for Input Actions

All Input Actions have some or all of the following parameters: Destination
The zone(s) that will be included in the broadcast. This may be left blank if access panel keys are used for zone selection.

Repetitions
Set the number of times the input action should be repeated.

  • Check the Loop box to make the repetition go in a loop

Priority
The priority of the broadcast.

  • Check the Replace box to make this broadcast replace other broadcasts with the same Priority.

This is usually used for Programs. If the box is not checked, other broadcasts with the same priority will be regarded as busy.
Events with higher priority will get the zones for the broadcast, while events with lower priority will be queued by default. The lower the number, the higher the priority.

Chime
Select the chime that will sound before the audio broadcast.