Advanced Audio Program Control

From exigoWiki
Jump to navigation Jump to search

The Advanced Audio Program feature is used to distribute background music from external radios, MP3 players, etc. to loudspeaker zone(s).
The background music can be turned on or off from an Access Panels (DAK key) or from a Control Input.
The difference between the Audio Program Control and the Advanced Audio Program Control is that with the Advanced Audio Program Control it is possible to step between several external audio sources.

Connection of Audio Program Source

An analog audio source can be connected to Line-In of the following devices:

  • ESC System Controller
  • ENA Amplifier
  • TFIE Kit
Connecting an audio source to an amplifier or to the controller


It is also possible to use the optional AGA Board.

Assigning an Audio Program Source to a Line Input

An Audio Line Input can be used for several purposes, and Audio Program is one of them. From the EMT tool, you must dedicate a Line Input for Audio Program distribution:

  1. In Components view, open External Connections
  2. In System, identify the Controller, the Amplifier or the TKIE kit to be used as Audio Program source, and expand to Audio Lines > Line Input
  3. Drag Audio Program Source to the Line Input
  4. A dialog box appears - select the Audio Program channel number. If there are several audio program sources, you would normally start with program 1 and so on.
Assigning an Audio Program Source to the input of the ESC Controller


Program Sequences

Before assigning advanced audio program to DAK(s), one or more Program Sequences must be defined.
Program Sequences editing is done in EMT:

  • System > Program Sequence
Program Sequences


  • Click the Add or Delete icon (top right in Program Sequence) to add or delete a program sequence.

Name: The name for the Program Sequence.

Sequence Number: The number for the Program Sequence.

Audio Programs: The Audio Programs in the specified sequence.

Configuration

  • Drag Advanced Audio Program Control to press_action on the desired key of the Access Panel.
Assigning Advanced Audio Program Control to a DAK


  • Select the desired Program Sequence,Step Direction and Destination.
Advanced Audio Program Control


Parameter Details

Advanced Audio Program Control - Parameter details


Program Sequence
The Program Sequence that will be used.

Step Direction
The step direction can be Up or Down.

Disable Rollover
Possible to disable rollover when stepping through the program sequence.

Destination
Possible to select both zones and outputs.

Audio Codec
Select between using system settings (Default) or G.722.

Priority
The priority of the broadcast.

Availability

This function is available on Exigo 1.3.3.1 and newer.