Difference between revisions of "Setting up a small system"
(→Step 3: Secondary System Controller) |
|||
(144 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
+ | [[File:Exigo_Small_System.JPG|thumb|right|400px|Exigo small system]] | ||
− | This | + | This article explains how to setup and configure a small Exigo system with one '''[[ESC1]]''' Controller, one '''[[ENA2200]]''' Amplifier and one '''[[ECPIR-3P]]''' Access panel. <br> |
+ | The system will be programmed with 2 Zones. <br> | ||
+ | With the PPT button we will configure Live Speech on both zones. | ||
− | + | {{Note}} Before you start configure it is important that all devices have been updated to the latest software/firmware. <br> Use only software/firmware from the same Exigo package. | |
− | |||
− | Table below lists IP range for a small system with one amplifier and on access panel. All subnets are set to 255.255.255.0 | + | == Step 1: IP address and Directory number == |
+ | Each device will need to be configured with an [[IP Configuration | '''IP address''']] and subnet which is in range of the AMC-IP card.<br> | ||
+ | In addition each device also need a [[Directory Numbers | '''directory number''']]. | ||
+ | |||
+ | Table below lists IP range for a small system with one amplifier and on access panel.<br> | ||
+ | All subnets are set to '''255.255.255.0''' <br> | ||
+ | Default '''Gateway''' is set to '''10.1.0.1''' | ||
{| class="wikitable" | {| class="wikitable" | ||
!Device | !Device | ||
!IP | !IP | ||
− | ! | + | !Directory number |
|- | |- | ||
|PSC | |PSC | ||
Line 15: | Line 23: | ||
| | | | ||
|- | |- | ||
− | | | + | |ESC1 |
|10.1.0.20 | |10.1.0.20 | ||
|013010 | |013010 | ||
Line 28: | Line 36: | ||
|} | |} | ||
+ | == Step 2: Primary System Controller Setup == | ||
+ | Open up the front of the '''ESC1 System Controller'''. Connect your computer to '''eth0'''. | ||
+ | |||
+ | # Open a web browser and enter the default IP address of port npe_eth0: '''169.254.1.5''' | ||
+ | # Log in with username: '''admin''' and password: '''alphaadmin''' | ||
+ | # Check the software version and if [[Primary System Controller Upgrade | '''necessary update the software''']]. | ||
+ | # Select System '''Configuration''' > '''Interfaces''' | ||
+ | |||
+ | |||
+ | [[File:Amc IP Interface 1.png|thumb|left|500px|Web Interface for the Primary System Controller]] | ||
+ | <br style="clear:both;" /> | ||
+ | * Enter the appropriate IP address (10.1.10.21) in the '''npe_eth1''' field. | ||
+ | |||
+ | In additional to setting the IP address you must also: | ||
+ | * Check the [[Firewall Settings | '''firewall settings''']]. | ||
+ | * Set the [[NTP Settings | '''NTP server''']]. | ||
+ | * Set the [https://exigo.zenitel.com/index.php/IP_Configuration#Defining_a_Default_Gateway '''Default Gateway''']. | ||
+ | |||
+ | == Step 3: Secondary System Controller Setup == | ||
+ | Connect your computer to '''eth1''' (on the back of the ESC1 System Controller). | ||
+ | |||
+ | To find the IP address of the Secondary System Controller: | ||
+ | * Turn the menu selection knob on the system controller to select '''Settings''' > '''Network''' to see the IP address on the display. | ||
+ | |||
+ | To configure the '''IP address''' and '''directory number''': | ||
+ | # Open a web browser and enter IP address: 169.254.x.x | ||
+ | # Log in with username: '''admin''' and password: '''alphaadmin''' | ||
+ | # Check the software version and if [[Secondary System Controller Update | '''necessary update the software''']]. | ||
+ | # Select Station '''Main''' > '''Main Settings''' | ||
+ | |||
+ | |||
+ | [[File:Secondary Controller Settings 1.png|thumb|left|600px|Web interface for the Secondary System Controller]] | ||
+ | <br style="clear:both;" /> | ||
+ | |||
+ | Set the following values: | ||
+ | * Station Mode: '''Use Exigo''' | ||
+ | * Registration Settings: | ||
+ | ** Primary System Controller address: '''10.1.0.21''' (IP address previously set for PSC) | ||
+ | ** Directory Number: '''013010''' (corresponds to the Directory Number automatically assigned to the system controller in the Exigo Management Tool) | ||
+ | *IP Settings: '''Static IP''' | ||
+ | ** IP-address: '''10.1.0.20''' | ||
+ | ** Subnet-mask: '''255.255.255.0''' | ||
+ | ** Gateway: '''10.1.0.1''' | ||
+ | |||
+ | == Step 4: ENA Amplifier Setup == | ||
+ | Connect your computer to '''eth1''' (on the back of the ENA Amplifier). | ||
+ | |||
+ | To find the IP address of the ENA Amplifier: | ||
+ | *Turn the menu selection knob on the Amplifier to select '''Settings''' > '''Network''' to see the IP address on the display. | ||
+ | |||
+ | To configure the '''IP address''' and '''directory number''': | ||
+ | # Open a web browser and enter IP address: 169.254.x.x | ||
+ | # Log in with username: '''admin''' and password: '''alphaadmin''' | ||
+ | # Check the software version and if [[Exigo Devices Upgrade | '''necessary update the software''']]. | ||
+ | # Select '''Station Main''' > '''Main Settings''' | ||
+ | |||
+ | |||
+ | [[File:ENA_Settings_1.png|thumb|left|600px|Web Interface for the ENA2200 Amplifier]] | ||
+ | <br style="clear:both;" /> | ||
+ | |||
+ | |||
+ | Set the following values: | ||
+ | * Station Mode: '''Use Exigo''' | ||
+ | * Registration Settings: | ||
+ | * Primary System Controller address: '''10.1.0.21''' (IP address previously set for PSC) | ||
+ | **Directory Number: '''012010''' (corresponds to the Directory Number automatically assigned to the system controller in the Exigo Management Tool) | ||
+ | *IP Settings: '''Static IP''' | ||
+ | ** IP-address: '''10.1.0.30''' | ||
+ | ** Subnet-mask: '''255.255.255.0''' | ||
+ | ** Gateway: '''10.1.0.1''' | ||
+ | |||
+ | == Step 5: ECPIR-3P Setup == | ||
+ | |||
+ | Configuration is done via the access panel’s web interface. After making sure that the access panel is connected to the same LAN and logical subnet as your PC, follow the procedure described below. | ||
+ | |||
+ | To configure the '''IP address''' and '''directory number''': | ||
+ | # Open a web browser and enter IP address: 169.254.x.x | ||
+ | # Log in with username: '''admin''' and password: '''alphaadmin''' | ||
+ | # Check the software version and if [[Exigo Devices Upgrade | '''necessary update the software''']]. | ||
+ | # Select '''Station Main''' > '''Main Settings''' | ||
+ | |||
+ | |||
+ | [[File:ECPIR_Settings_1.JPG|thumb|left|600px|Web Interface for the ECPIR-3P]] | ||
+ | <br style="clear:both;" /> | ||
+ | |||
+ | |||
+ | Set the following values: | ||
+ | * Station Mode: '''Use Exigo''' | ||
+ | * Registration Settings: | ||
+ | * Primary System Controller address: '''10.1.0.21''' (IP address previously set for PSC) | ||
+ | **Directory Number: '''011010''' (corresponds to the Directory Number automatically assigned to the system controller in the Exigo Management Tool) | ||
+ | *IP Settings: '''Static IP''' | ||
+ | ** IP-address: '''10.1.0.50''' | ||
+ | ** Subnet-mask: '''255.255.255.0''' | ||
+ | ** Gateway: '''10.1.0.1''' | ||
+ | |||
+ | == Step 6: Install Exigo Management Tool (EMT) == | ||
+ | |||
+ | Install EMT on your computer. See this page for details: [[Installing EMT]] | ||
+ | |||
+ | == Step 7: Exigo Management Tool Setup == | ||
+ | |||
+ | * Start the Exigo Management Tool | ||
+ | * Click '''Projects''' at the lower-left of the window. | ||
+ | |||
+ | [[File:EMT_Setup_1.png|thumb|left|500px|EMT Projects overview]] | ||
+ | <br style="clear:both;" /> | ||
+ | |||
+ | * Click '''New''' | ||
+ | |||
+ | [[File:EMT Setup 2.png|thumb|left|500px|Database setup wizard]] | ||
+ | <br style="clear:both;" /> | ||
+ | |||
+ | * Click the '''New Database''' tab | ||
+ | * Click the right-arrow icon at the bottom of the window | ||
+ | |||
+ | [[File:EMT Setup 3.png|thumb|left|500px|Database setup wizard - Singel or A-B System]] | ||
+ | <br style="clear:both;" /> | ||
+ | |||
+ | * Enter a project name in the '''Project''' field | ||
+ | * Select the '''Singel System''' tab | ||
+ | * Click the right-arrow icon at the bottom of the window | ||
+ | |||
+ | [[File:EMT Setup 4.png|thumb|left|500px|Database setup wizard - Zones, Amplifiers an IP address]] | ||
+ | <br style="clear:both;" /> | ||
+ | |||
+ | * Set 2 for the '''Number of Discrete Zones''' | ||
+ | * Enter IP address '''10.1.0.21''' in '''Domain Address''' | ||
+ | * Click the right-arrow icon at the bottom of the window | ||
+ | |||
+ | [[File:EMT Setup 5.png|thumb|left|500px|Database setup wizard - Monitoring]] | ||
+ | <br style="clear:both;" /> | ||
+ | |||
+ | Select the desired monitoring: | ||
+ | * Select '''Eth1''' for the '''Rack Devices''' | ||
+ | * Select '''AC Monitoring''' | ||
+ | * Select '''Eth1''' for the '''Access Panels and Kits''' | ||
+ | |||
+ | [[File:EMT Setup 6.png|thumb|left|500px|Database setup wizard - Advanced Settings]] | ||
+ | <br style="clear:both;" /> | ||
+ | |||
+ | Select the desired '''Advanced Settings''': | ||
+ | |||
+ | * Default setting is OK. This can be changed later if needed. | ||
+ | |||
+ | * Click the right-arrow icon at the bottom of the window to display a project summary | ||
+ | |||
+ | [[File:EMT Setup 7.png|thumb|left|500px|Database setup wizard - Summary]] | ||
+ | <br style="clear:both;" /> | ||
+ | |||
+ | * Click '''Finish''' to complete the setup of the project | ||
+ | |||
+ | After setup, your Exigo system should look something like the following: | ||
+ | |||
+ | [[File:EMT Setup 8.png|thumb|left|500px|EMT - Project view]] | ||
+ | <br style="clear:both;" /> | ||
+ | |||
+ | ==Step 8: Exigo Management Tool System Configuration== | ||
+ | |||
+ | When the Project is created in EMT it is time to do configuration on the System. | ||
+ | |||
+ | === Assigning the '''ECPIR-3P''' Access Panel to the System: === | ||
+ | |||
+ | * Click '''Components''' at the lower-left of the window. | ||
+ | * Click '''Devices''' from the menu box | ||
+ | * Under Console Mounted Access Panels drag-and-drop '''ECPIR-3P''' to '''System''' | ||
+ | [[File:EMT Config 1.png|thumb|left|500px|EMT Components view - adding ECPIR-3P panel]] | ||
+ | <br style="clear:both;" /> | ||
+ | The access panel will now appear as '''ECPIR-3P 1''' in the device list under '''System'''. | ||
− | == | + | === Assigning '''Channels''' on '''Amplifier''' to '''Zones''': === |
− | |||
− | + | * Select '''ENA2200 A1''' > '''Audio Lines''' > '''Line''' > '''Amplifier output channel 1''' | |
− | + | * Drag-and-drop '''Amplifier output channel 1''' to '''Zone 1''' under '''PA Zones''' | |
− | |||
− | [[File: | + | [[File:EMT Config 2.png|thumb|left|600px|EMT - assigning output channels to zones]] |
<br style="clear:both;" /> | <br style="clear:both;" /> | ||
− | |||
− | == | + | * Repeat the procedure to assign '''channel 2''' on the amplifiers to '''Zone 2'''. |
− | + | ||
+ | === Assigning Zone to the PPT Button === | ||
+ | |||
+ | * Select '''System''' > '''ECPIR-3P 1''' > '''Programmable Keys''' > '''ptt''' > '''press_actions''' | ||
+ | |||
+ | [[File:EMT Config 3.JPG|thumb|left|600px|EMT - assigning zones to the PTT button]] | ||
+ | <br style="clear:both;" /> | ||
+ | |||
+ | * In the detailed view select '''All''' under '''Destination''' | ||
+ | |||
+ | Do the same for '''release_action''': | ||
+ | * Select '''System''' > '''ECPIR-3P 1''' > '''Programmable Keys''' > '''ptt''' > '''press_release''' | ||
+ | * In the detailed view select '''All''' under '''Destination''' | ||
+ | |||
+ | == Step 9: Upload database == | ||
+ | |||
+ | In the Navigation pane, select '''Projects''' view. | ||
+ | |||
+ | [[File:EMT Upload 1.png|thumb|left|500px|EMT - uploading the database]] | ||
+ | <br style="clear:both;" /> | ||
+ | |||
+ | * Press '''Send''' to upload the new configuration to the Exigo system | ||
+ | |||
+ | The system shall now be working. If you push PTT it shall be possible to make a live speech to both zones. | ||
− | |||
− | |||
− | [[Category: | + | [[Category:Getting started]] |
Latest revision as of 09:16, 19 October 2018
This article explains how to setup and configure a small Exigo system with one ESC1 Controller, one ENA2200 Amplifier and one ECPIR-3P Access panel.
The system will be programmed with 2 Zones.
With the PPT button we will configure Live Speech on both zones.
Before you start configure it is important that all devices have been updated to the latest software/firmware.
Use only software/firmware from the same Exigo package.
Contents
- 1 Step 1: IP address and Directory number
- 2 Step 2: Primary System Controller Setup
- 3 Step 3: Secondary System Controller Setup
- 4 Step 4: ENA Amplifier Setup
- 5 Step 5: ECPIR-3P Setup
- 6 Step 6: Install Exigo Management Tool (EMT)
- 7 Step 7: Exigo Management Tool Setup
- 8 Step 8: Exigo Management Tool System Configuration
- 9 Step 9: Upload database
Step 1: IP address and Directory number
Each device will need to be configured with an IP address and subnet which is in range of the AMC-IP card.
In addition each device also need a directory number.
Table below lists IP range for a small system with one amplifier and on access panel.
All subnets are set to 255.255.255.0
Default Gateway is set to 10.1.0.1
Device | IP | Directory number |
---|---|---|
PSC | 10.1.0.21 | |
ESC1 | 10.1.0.20 | 013010 |
ENA | 10.1.0.30 | 012010 |
ECPIR-3P | 10.1.0.50 | 011010 |
Step 2: Primary System Controller Setup
Open up the front of the ESC1 System Controller. Connect your computer to eth0.
- Open a web browser and enter the default IP address of port npe_eth0: 169.254.1.5
- Log in with username: admin and password: alphaadmin
- Check the software version and if necessary update the software.
- Select System Configuration > Interfaces
- Enter the appropriate IP address (10.1.10.21) in the npe_eth1 field.
In additional to setting the IP address you must also:
- Check the firewall settings.
- Set the NTP server.
- Set the Default Gateway.
Step 3: Secondary System Controller Setup
Connect your computer to eth1 (on the back of the ESC1 System Controller).
To find the IP address of the Secondary System Controller:
- Turn the menu selection knob on the system controller to select Settings > Network to see the IP address on the display.
To configure the IP address and directory number:
- Open a web browser and enter IP address: 169.254.x.x
- Log in with username: admin and password: alphaadmin
- Check the software version and if necessary update the software.
- Select Station Main > Main Settings
Set the following values:
- Station Mode: Use Exigo
- Registration Settings:
- Primary System Controller address: 10.1.0.21 (IP address previously set for PSC)
- Directory Number: 013010 (corresponds to the Directory Number automatically assigned to the system controller in the Exigo Management Tool)
- IP Settings: Static IP
- IP-address: 10.1.0.20
- Subnet-mask: 255.255.255.0
- Gateway: 10.1.0.1
Step 4: ENA Amplifier Setup
Connect your computer to eth1 (on the back of the ENA Amplifier).
To find the IP address of the ENA Amplifier:
- Turn the menu selection knob on the Amplifier to select Settings > Network to see the IP address on the display.
To configure the IP address and directory number:
- Open a web browser and enter IP address: 169.254.x.x
- Log in with username: admin and password: alphaadmin
- Check the software version and if necessary update the software.
- Select Station Main > Main Settings
Set the following values:
- Station Mode: Use Exigo
- Registration Settings:
- Primary System Controller address: 10.1.0.21 (IP address previously set for PSC)
- Directory Number: 012010 (corresponds to the Directory Number automatically assigned to the system controller in the Exigo Management Tool)
- IP Settings: Static IP
- IP-address: 10.1.0.30
- Subnet-mask: 255.255.255.0
- Gateway: 10.1.0.1
Step 5: ECPIR-3P Setup
Configuration is done via the access panel’s web interface. After making sure that the access panel is connected to the same LAN and logical subnet as your PC, follow the procedure described below.
To configure the IP address and directory number:
- Open a web browser and enter IP address: 169.254.x.x
- Log in with username: admin and password: alphaadmin
- Check the software version and if necessary update the software.
- Select Station Main > Main Settings
Set the following values:
- Station Mode: Use Exigo
- Registration Settings:
- Primary System Controller address: 10.1.0.21 (IP address previously set for PSC)
- Directory Number: 011010 (corresponds to the Directory Number automatically assigned to the system controller in the Exigo Management Tool)
- IP Settings: Static IP
- IP-address: 10.1.0.50
- Subnet-mask: 255.255.255.0
- Gateway: 10.1.0.1
Step 6: Install Exigo Management Tool (EMT)
Install EMT on your computer. See this page for details: Installing EMT
Step 7: Exigo Management Tool Setup
- Start the Exigo Management Tool
- Click Projects at the lower-left of the window.
- Click New
- Click the New Database tab
- Click the right-arrow icon at the bottom of the window
- Enter a project name in the Project field
- Select the Singel System tab
- Click the right-arrow icon at the bottom of the window
- Set 2 for the Number of Discrete Zones
- Enter IP address 10.1.0.21 in Domain Address
- Click the right-arrow icon at the bottom of the window
Select the desired monitoring:
- Select Eth1 for the Rack Devices
- Select AC Monitoring
- Select Eth1 for the Access Panels and Kits
Select the desired Advanced Settings:
- Default setting is OK. This can be changed later if needed.
- Click the right-arrow icon at the bottom of the window to display a project summary
- Click Finish to complete the setup of the project
After setup, your Exigo system should look something like the following:
Step 8: Exigo Management Tool System Configuration
When the Project is created in EMT it is time to do configuration on the System.
Assigning the ECPIR-3P Access Panel to the System:
- Click Components at the lower-left of the window.
- Click Devices from the menu box
- Under Console Mounted Access Panels drag-and-drop ECPIR-3P to System
The access panel will now appear as ECPIR-3P 1 in the device list under System.
Assigning Channels on Amplifier to Zones:
- Select ENA2200 A1 > Audio Lines > Line > Amplifier output channel 1
- Drag-and-drop Amplifier output channel 1 to Zone 1 under PA Zones
- Repeat the procedure to assign channel 2 on the amplifiers to Zone 2.
Assigning Zone to the PPT Button
- Select System > ECPIR-3P 1 > Programmable Keys > ptt > press_actions
- In the detailed view select All under Destination
Do the same for release_action:
- Select System > ECPIR-3P 1 > Programmable Keys > ptt > press_release
- In the detailed view select All under Destination
Step 9: Upload database
In the Navigation pane, select Projects view.
- Press Send to upload the new configuration to the Exigo system
The system shall now be working. If you push PTT it shall be possible to make a live speech to both zones.