Difference between revisions of "Local Mute"

From exigoWiki
Jump to navigation Jump to search
(Audio activity)
(Parameter details)
 
(52 intermediate revisions by 2 users not shown)
Line 1: Line 1:
[[Category:Exigo features]]
+
[[File:Local mute 1.JPG|thumb|right|450px|Local Mute to prevent feedback]]
Local mute is a common PA function where one or more speakers are disconnected when a specific access panel is used. This is commonly used when there are a high probablity of feedback.
+
[[Control Outputs]] are configured by defining one or more actions to be triggered on an output event.
 +
 
 +
'''Local Mute''' is used when an output shall mute one or more speakers to prevent audio feedback. <br>
 +
Local mute is also used when there is a need to do a manual initiation of local mute with the input function '''[[Local Mute Control]]'''.
 +
 
 +
It is possible to define maximum 99 local mutes.
 +
 
 +
== Assigning Local Mute to a Control Output ==
 +
To assign the function Local Mute to an Control Output:
 +
#In '''Components''' view, open '''Output Actions'''
 +
#In '''System''', identify the Controller, the Amplifier or the Access Panel to be used, and expand to '''Device > Control Outputs'''.
 +
#Drag '''Local Mute''' to the '''Control Output''' you want to use.
 +
 
 +
[[File:Local mute 2.JPG|thumb|left|500px|Assigning Local Mute to a Control Output]]
 +
<br style="clear:both;" />
 +
 
 +
== Configuration ==
 +
=== When a specific Source sends audio to a specified Zone, the output will be operated ===
 +
The output is used to mute a nearby loudspeaker
 +
 
 +
#Drag '''Local Mute''' to the desired Control Output.
 +
#Select the desired source in '''Source'''.
 +
#In '''Zone''' select the zone that the desired speaker is part of.
 +
 
 +
[[File:Local mute 3.PNG|thumb|left|500px|Audio Activity configuration]]
 +
<br style="clear:both;" />
 +
 
 +
In this example audio from the ECPIR-3P to Zone 1 will trig Control Output 1. This output can then be used to mute a speaker in Zone 1.
 +
 
 +
== Example of use ==
 +
It is possible to mute an IP Speaker based on a specified SIP Station doing announcement in Exigo. <br>
 +
This example can be found [[External_Audio_Sources#Example_-_Mute_IP_Speaker_based_on_specified_SIP_Station| here]].
 +
 
 +
== Parameter details ==
 +
 
 +
[[File:Local mute 4.png|left|thumb|500px|Local Mute - Parameter details]]
 +
<br style="clear:both;" />
 +
 
 +
'''<u>Idle State</u>''' <br>
 +
Sets the idle state for the output. The options are '''Normally Open''' or '''Normally Closed'''.
 +
 
 +
'''<u>Source</u>''' <br>
 +
The source that will trigger the control output. The Source field can only contain Local Mute, audio inputs and access panels. <br>
 +
The '''Local mute #''' options can be triggered from panels to activate local muting in an alarm situation. <br>
 +
If Source is not specified, it will be ignored when checking whether the conditions for the audio activity triggering are present or not.
 +
 
 +
'''<u>Zone</u>''' <br>
 +
The zones in which the output on an activity is triggered.
 +
If Zone is not specified, it will be ignored when checking whether the conditions for the audio activity triggering are present or not.
 +
 
 +
===Advanced Options:===
 +
::'''Delay Activation:''' Delays control output activation for the stipulated number of seconds when triggered.  
  
==Wiring example==
+
::'''Limit High Not OK:''' When the Control Output is cleared, and feedback voltage is at or above this value, the output is considered fed with alien voltage.
See [[Wiring Local mute]]
 
  
==Configuration==
+
::'''Limit Low OK:''' When the Control Output is set, and feedback voltage is above this value, the output is considered active OK.
In Exigo a [[Audio activity]] or a [[Local mute output]] function needs to be configured on the relevant control output
 
  
===Local mute output action===
+
::'''On Lost Connection:''' Fall back to this state on lost connection with ESC. Available Settings: '''Idle State, No Change, Open, Closed'''.
[[File:Local_mute_automatic.png|500x250px|thumb|alt=Local mute configured for one access panel]]
 
In the local mute output function only the access panel and zone needs to be set. With the settings shown here the local mute will only trigger the control output when "ECPIR-3P A1" sends live speech to Zone 1.
 
  
===Audio activity===
+
[[Category:Exigo features]]
[[File:Audio_activity_localmute.png|500x250px|thumb|alt=Audio activity configured for local mute]]
+
[[Category:Output Actions]]
Image shows how Control output 1 should trigger when "ECPIR-3P A1" is used in Zone 1. This implies that the access panel is placed in an area covered by zone 1. If the access panel sends [[Live speech]] into zone 1 the function will trigger, but if it sends the live speech to any other zone it will not trigger. Other activity, such as message control or similar will not trigger this activity as the source must be the access panel itself.
 

Latest revision as of 12:28, 18 October 2018

Local Mute to prevent feedback

Control Outputs are configured by defining one or more actions to be triggered on an output event.

Local Mute is used when an output shall mute one or more speakers to prevent audio feedback.
Local mute is also used when there is a need to do a manual initiation of local mute with the input function Local Mute Control.

It is possible to define maximum 99 local mutes.

Assigning Local Mute to a Control Output

To assign the function Local Mute to an Control Output:

  1. In Components view, open Output Actions
  2. In System, identify the Controller, the Amplifier or the Access Panel to be used, and expand to Device > Control Outputs.
  3. Drag Local Mute to the Control Output you want to use.
Assigning Local Mute to a Control Output


Configuration

When a specific Source sends audio to a specified Zone, the output will be operated

The output is used to mute a nearby loudspeaker

  1. Drag Local Mute to the desired Control Output.
  2. Select the desired source in Source.
  3. In Zone select the zone that the desired speaker is part of.
Audio Activity configuration


In this example audio from the ECPIR-3P to Zone 1 will trig Control Output 1. This output can then be used to mute a speaker in Zone 1.

Example of use

It is possible to mute an IP Speaker based on a specified SIP Station doing announcement in Exigo.
This example can be found here.

Parameter details

Local Mute - Parameter details


Idle State
Sets the idle state for the output. The options are Normally Open or Normally Closed.

Source
The source that will trigger the control output. The Source field can only contain Local Mute, audio inputs and access panels.
The Local mute # options can be triggered from panels to activate local muting in an alarm situation.
If Source is not specified, it will be ignored when checking whether the conditions for the audio activity triggering are present or not.

Zone
The zones in which the output on an activity is triggered. If Zone is not specified, it will be ignored when checking whether the conditions for the audio activity triggering are present or not.

Advanced Options:

Delay Activation: Delays control output activation for the stipulated number of seconds when triggered.
Limit High Not OK: When the Control Output is cleared, and feedback voltage is at or above this value, the output is considered fed with alien voltage.
Limit Low OK: When the Control Output is set, and feedback voltage is above this value, the output is considered active OK.
On Lost Connection: Fall back to this state on lost connection with ESC. Available Settings: Idle State, No Change, Open, Closed.