Difference between revisions of "Local Mute"

From exigoWiki
Jump to navigation Jump to search
(Advanced Options:)
(Parameter details)
Line 35: Line 35:
  
 
'''Idle State:''' Sets the idle state for the output. The options are Normally Open or Normally Closed  
 
'''Idle State:''' Sets the idle state for the output. The options are Normally Open or Normally Closed  
 
 
  
 
'''Source:''' The source that will trigger the control output. The Source field can contain audio inputs, access panels and [[Local Mute Control|'''Local Mute Control''']] input actions.  
 
'''Source:''' The source that will trigger the control output. The Source field can contain audio inputs, access panels and [[Local Mute Control|'''Local Mute Control''']] input actions.  

Revision as of 11:01, 26 March 2018

Local Mute to prevent feedback

Control Outputs are configured by defining one or more actions to be triggered on an output event.

Local mute is a common PA function where one or more speakers are disconnected(muted) when a specific access panel is used.
This is commonly used when there are a high probability of feedback.

In addition to use Control Outputs to control local mute it is also possible to direct mute an audio line output.
More information can be found here.

It is possible to define maximum 99 local mutes.

Assigning Local Mute to a Control Output

To assign the function Local Mute to an Control Output:

  1. In Components view, open Output Actions
  2. In System, identify the Controller, the Amplifier or the Access Panel to be used, and expand to Device > Control Outputs.
  3. Drag Local Mute to the Control Output you want to use.
Assigning Local Mute to a Control Output


Configuration

When a specific Source sends audio to a specified Zone, the output will be operated

The output is used to mute a nearby loudspeaker

  1. Drag Local Mute to the desired Control Output.
  2. Select the desired source in Source.
  3. In Zone select the zone that the desired speaker is part of.
Audio Activity configuration


In this example audio from the ECPIR-3P to Zone 1 will trig Control Output 1. This output can then be used to mute a speaker in Zone 1.

Parameter details

Idle State: Sets the idle state for the output. The options are Normally Open or Normally Closed

Source: The source that will trigger the control output. The Source field can contain audio inputs, access panels and Local Mute Control input actions. The Local mute 'id #' options refer to the local mute control input action that can be assigned to a DAK or a control input. If Source is not specified, it will be ignored when checking whether the conditions for the audio activity triggering are present or not.

Zone: The zones in which the output on an activity is triggered. If Zone is not specified, it will be ignored when checking whether the conditions for the audio activity triggering are present or not.

Advanced Options:

Delay Activation: Delays control output activation for the stipulated number of seconds when triggered.
Limit High Not OK: When the Control Output is cleared, and feedback voltage is at or above this value, the output is considered fed with alien voltage.
Limit Low OK: When the Control Output is set, and feedback voltage is above this value, the output is considered active OK.
On Lost Connections: Fall back to this state on lost connection with ESC.