Difference between revisions of "Local Mute Control"

From exigoWiki
Jump to navigation Jump to search
Line 1: Line 1:
'''Local Mute Control''' will force any Control Output that is being used (and configured with ''Local Mute'' as '''Source''') to trigger. As with other broadcasts, it will be added to the queue if other broadcasts with higher priority are active in the selected zone.
+
'''Local Mute Control''' will force any Control Output that is being used (and configured with '''Local Mute''' as '''Source''') to trigger. As with other broadcasts, it will be added to the queue if other broadcasts with higher priority are active in the selected zone.
  
 
* Drag-and-drop [[Input Actions]] -> Local Mute Control to:
 
* Drag-and-drop [[Input Actions]] -> Local Mute Control to:
'''Amplifier -> [[Control Inputs]] -> CI -> CI_1-CI_6 -> on_action/off_action
+
'''Amplifier -> [[Control Inputs]] -> CI -> CI_1-CI_6 -> on_action/off_action'''
  
 
or
 
or
  
[[access panels|Access Panel]] -> Programmable Keys -> Key -> p1-px -> press_action/release_action
+
'''[[access panels|Access Panel]] -> Programmable Keys -> Key -> p1-px -> press_action/release_action'''
  
 
[[File:Local_Mute_Control_1.png|left]]
 
[[File:Local_Mute_Control_1.png|left]]

Revision as of 10:51, 24 June 2016

Local Mute Control will force any Control Output that is being used (and configured with Local Mute as Source) to trigger. As with other broadcasts, it will be added to the queue if other broadcasts with higher priority are active in the selected zone.

Amplifier -> Control Inputs -> CI -> CI_1-CI_6 -> on_action/off_action

or

Access Panel -> Programmable Keys -> Key -> p1-px -> press_action/release_action

Local Mute Control 1.png


Mute ID The Local Mute to be triggered. This is the source in the control output that directs the actual physical function.

Activation Start, Stop or Toggle the Local Mute.

Destination The zones in which Local Mute will be started. The zone and source must correspond to the function configured in the output.

Priority The priority of the broadcast. The muting will be active as long as the activity in the selected zone has a lower priority than the one set here. For example, the operator wants to mute GA with Priority 20, but he wants to hear the Abandon Alarm with Priority 15. In this case, Priority can be set to 18 here.

Advanced options

  • Check the Use Default Parameters box to use default values for the parameters
  • Enable Timeout – decides whether the function will timeout or not
  • Timeout – the amount of time in seconds that the broadcast will be active. Typically, this is set to
  • Deactivate Mute On – deactivate mute when the alarm state changes in the zone/broadcast:
    • On Alarm start and stop - Deactivate mute on both start and stop
    • On Alarm start - Deactivate mute on start of a new alarm that has lower priority than the one set here. Used when one wants the new alarm to be heard.
    • On Alarm stop - Deactivate mute on stop. Used when the manual triggering of the mute should be turned off when the alarm stops.