Devices with Control Outputs available

This article describes the control outputs in the Exigo system in general.

  • Rack Devices (Controllers/Amplifiers):
    • 6 NO/NC relays and 24V DC outputs (200 mA)
  • Access Panels:
    • 2 NO/NC relays, and 6 digital outputs
  • Outputs are used e.g. for:
    • Visual Call / Audio Indication
    • Local Mute of nearby loudspeakers
    • Volume Override

Control Outputs - Connections

Connections on Rack Devices:

Rack Devices


Connections on Access Panels:

Access Panels


Configuration

Configuration of Control Outputs are done in EMT:

Assigning Audio Activity on Control Output 1


  • In Components view open Output Actions
  • In System, identify the device and expand to Control Outputs
  • Drag the desired Output Action to the Control Output > CO_x
  • Set relevant parameters in the dialog box that appears

Limitations

ENA Amplifiers

Relay Outputs:

  • Max 24 VDC, 60 W
  • Max 250 VAC, 125 VA

24 VDC Outputs:

  • 24 VDC, ±10%, 200 mA

Access Panels

Relay Outputs: 2 (250VAC/200VDC, 2A, 60W)