Difference between revisions of "Basic Troubleshooting"

From exigoWiki
Jump to navigation Jump to search
(Firewall (Filter) Settings)
Line 37: Line 37:
  
 
== Firewall (Filter) Settings ==
 
== Firewall (Filter) Settings ==
 +
By default [Category:EMT EMT] will open all necessary protocols in the firewall for the Primary System Comtroller.
 
Make sure that you open up for all required protocols in the firewall filter settings on the AMC-IP card.<br>
 
Make sure that you open up for all required protocols in the firewall filter settings on the AMC-IP card.<br>
 
A guide on firewall settings can be found [[Firewall Settings | here]].
 
A guide on firewall settings can be found [[Firewall Settings | here]].

Revision as of 15:40, 16 November 2017

This article describes basic troubleshooting for the Exigo system.
If the Exigo system is not working properly, the following tips/advice might be useful for troubleshooting.

Firmware

Note: Before you start configure the Exigo system it is important that all devices have been updated to the latest software/firmware. 
Use only software/firmware from the same Exigo package.

The Exigo software releases come in packages including software for:

  • EMT
  • Primary System Controller
  • Access Panels, Network Amplifiers (ENA) and Secondary System Controller
  • CRM Access Panel
  • Flowire

Make sure you are using the latest firmware from the same package.
Using firmware/software from different packages may cause problems.

IP Address and Directory Number

  • Make sure Domain Controller IP is correct on each device (Primary System Controller).
  • Make sure that all the devices have the correct IP address and directory number.

It is also important to set the default Gateway for each device.
Best practice is to use the x.x.x.1 address as the default Gateway.

Station List

After uploading the database to the system controller, it is possible to check the status of all the devices that are configured.

  • Log on to the Primary System Controller (AlphaWeb) with a web browser.
  • Select System Monitoring > Stations > Configured
AMC-IP web interface - Stations


Information that can be found here:

  • Status of all devices that are configured in the database.
  • Software version on each device.
  • Registration Counter - Shows the number of times a station has registered to the Primary System Controller since last reset.

Web Interface Access

Each device is equipped with a web interface. Make sure that it is possible to access each device via the interface.
This will also confirm that all devices are online.

Firewall (Filter) Settings

By default [Category:EMT EMT] will open all necessary protocols in the firewall for the Primary System Comtroller. Make sure that you open up for all required protocols in the firewall filter settings on the AMC-IP card.
A guide on firewall settings can be found here.

Restart Devices

Restarting devices may help to resolve problems with the system.

From the web interface on the AMC-IP board, it is possible to do a chilly restart.

  • Go to System Maintenance > System Recovery
  • Click Chilly Restart
AMC-IP web interface - Chilly Restart


In many cases this will be sufficient to resolve the problem.
If this does not work, it may help to do a full restart of the devices (or turn the device off and then on again).

Factory Default

A factory default reset of a device may help to resolve some problems.
A guide on how to do factory default reset on various devices can be found here.

Logging

For more in-depth troubleshooting, it may be necessary to study the log files.
A guide on how to turn on logging can be found here.