ENA2400-DC

From exigoWiki
Revision as of 14:50, 24 November 2017 by Gsorensen (talk | contribs)
Jump to navigation Jump to search
ENA2400-DC.
ENA2400-DC

Exigo Network Amplifier

  • 2x 400 watt continuous GA effect
  • 2x 400 watt PA effect
  • Power efficient class D technology
  • 48 VDC power
  • Redundant Ethernet connections
  • Digital audio processing, equalizer and audio delay
  • Loudspeaker line monitoring
  • Input for backup amplifier


The Exigo Network Amplifier is designed for use in marine, offshore and other demanding environments.
The amplifier utilizes state-of-the-art class D amplifier technology to ensure high power efficiency and superb audio quality.

The amplifier connects to the Exigo system through native IP networking, and receives audio and control data, through standard 100 Mbps Ethernet. The design com prises two Ethernet connections, enabling redundant cabling between the amplifier and the network. The amplifier has DSP capabilities, allowing advanced functions like audio equalization and audio delay. The DSP is an integral part of the audio synchronization between all audio outputs in the Exigo system and alarm tone generators.

The amplifier monitors the speaker lines for shorts, overload and opens. A Line End Transponder (ELTSI) is required for reliable detection of an open or shorted line when the cables exceed 400 meters. More than one ELTSI can be connected to the same line, allowing monitoring of several branches on the speaker line. The amplifier also monitors control inputs, power, temperature, network connections and every other component required for reliable operation of essential services. Faults will be reported to the system controller, but will also be indicated locally on the amplifier.

The amplifier’s control inputs/outputs and audio inputs can be used locally by the amplifier (e.g. for PTT and audio from a handheld microphone) or they may be controlled by the system itself (e.g. audio input for background music).

Installation

Overview - Front

ENA2400


1 Mounting Flange The mounting flanges are used to mount the unit in 19” equipment racks
2 Ventilation Inlets The ventilation inlets should be kept free of obstacles and dust. Fans control the airflow based on internal temperature
3 Headphone Jack The headphone connection can be used to listen to the different audio streams in the Amplifier.
4 Status Indicators The status indicators are used to display the status of important parameters such as power supplies and faults
5 LCD Display The LCD screen displays status and a graphical user interface
6 Control Knob The control knob is used to select and execute menu items in the user interface. The knob can be rotated and pressed.
7 Integrated Handle These integrated handles make it easy to maneuver the unit, without adding to the installation depth
8 Ventilation Inlets The ventilation inlets should be kept free of obstacles and dust. Fans control the airflow based on internal temperature



Overview - Back

ENA2400


1 Ethernet Ports Redundant Ethernet connections for audio and control data
2 Serial Console Serial port connection for debugging and factory programming
3 Control Inputs 6 configurable control inputs. Each input is activated by closing the loop

between the two terminals

4 Fault Relay Output A switching relay (NO, NC & COM) kept in the active position between COM and NO as long as no faults are present in the device
5 Control Outputs Six configurable control outputs. Each is made of a switching relay (NO, NC and COM) in parallel with a 24VDC signal. The 24VDC part of the control output can source max 200mA and has overcurrent protection
6 Audio Inputs Microphone and line-in audio inputs for microphones or external audio sources
7 Speaker Outputs 100 and 70 volt outputs per channel. Each channel also has a low-power 8ohm output for single speakers. Each channel is equipped with inputs for connection to a hot-standby amplifier
8 Ground Connection Ground connection for grounding of the unit. This is connected in parallel with the ground connection in the AC power inlet
9 DC Power Inlet DC power inlet for 24 to 48 VDC
10 DC Power Switch Power switch for DC power
11 Standby Indicator Standby Indicator



Placement and Stacking

The amplifier is designed to deliver full power at ambient temperatures up to 55 °C. As long as the equipment rack is well ventilated, amplifiers can be stacked with no extra space between them. It is however recommended to add 1 HU between every group of 4 amplifiers.

Mounting

The amplifier’s mechanical construction is rigid enough to be mounted using only the four holes in the mounting flange to secure it to the rack. It is however considered good practice to mount support rails if the system is installed in a mobile environment.

Power Supply

The Amplifier shall be connected to the equipment rack’s primary and secondary (emergency) source of power.

Note.PNG
Only one power source may be connected if the power source itself is redundant
(e.g. UPS) or if the class/installation permits a single source of power


Observe.PNG
DC power input are equipped with a lock, preventing the plug from falling out.
Make sure that the plug is properly inserted, and that the lock is engaged

The requirements for the power rails are listed in the Technical Specifications for the amplifier. The cables used for the power shall be dimensioned accordingly to the voltage and current consumption of the amplifier.

Grounding

It is always good practice to ground the cabinet of equipment installed in racks. This ensures safety and good EMC. If the unit is powered entirely through the DC power inlet, the ground connection is the only way to connect the Amplifier to ground. The ground connection of the Amplifier should be connected to the equipment rack’s ground strip using a ground wire of at least 0.75 mm² (AWG 19).

Note.PNG
If the Amplifier isn’t connected to ground, it will not be able to detect ground
faults or short-circuits to ground

Ethernet Connections

The Amplifier shall be connected to the network using one or two Ethernet cables, depending on the system interconnection scheme.

Fault Relay

The Amplifier’s fault relay will trigger whenever a fault occurs in the amplifier. This relay is actively kept closed by the Amplifier so it will trigger even if the entire amplifier loses power. The connection to external equipment should be made according to the external equipment’s requirements. When no faults are present in the amplifier, an electrical connection is established between the COM and NO terminals of the fault relay. When a fault is detected, or the amplifier loses power, this connection is removed and a connection between COM and NC is established.

The fault relay should be routed from the Amplifier output to a terminal block in the equipment rack if required by the specific system.

Note.PNG
The fault relay on the system controller will trigger in parallel with that of the amplifier.
In most cases, it is sufficient to use only the fault relay on the system controller.

Control Inputs

The Control Inputs should be routed from the Amplifier screw terminal to terminal blocks in the equipment rack.

Control Outputs

The Control Outputs on the Amplifier should be routed to terminal blocks in accordance with the specific system’s requirements. Cable diameter used is max 1 mm2 flexible.

Audio Inputs

The two audio inputs on the Amplifier can be used for background music, external alarms or local microphone. The audio inputs should be routed to terminal blocks in the equipment rack or local audio sources.

Loudspeaker Connections

The Amplifier has three different options for loudspeaker connections: 8Ω, 70 volts and 100 volts. The 8Ω output is only intended for local monitoring of audio, and the power is therefore limited compared to the 70 and 100 volt lines.

ENA Speaker Connections.PNG


1 70 volt connection
2 100 volt connection
3 8Ω connection



The loudspeaker outputs from the amplifier should be routed to terminal blocks in the equipment rack according to system requirements.

Dimensions

ENA2400.
ENA2400 dimensions


Additional Documentation

For more documentation, please visit the Zenitel web page: https://www.zenitel.com/product/ena2400-dc