== Organizing Alarms == | == Organizing Alarms == | ||
− | Alarms can be organized and renamed using '''Exigo Management Tool (EMT)'''. | + | Alarms can be organized and renamed using the '''Exigo Management Tool (EMT)'''. |
=== Renaming Alarms === | === Renaming Alarms === | ||
− | For easy identification of an alarm they can be renamed to a more logical name. <br> | + | For easy identification of an alarm, they can be renamed to a more logical name. <br> |
− | + | To rename Alarms: | |
− | * | + | * Select '''System''' > '''Alarms''' |
− | * Select the Alarm you want to rename | + | * Select the Alarm you want to rename |
− | * Type in a new name in the '''Name''' field and | + | * Type in a new name in the '''Name''' field and click '''Done''' |
[[File:Alarm generator 3.JPG|thumb|left|700px|Organizing Alarms]] | [[File:Alarm generator 3.JPG|thumb|left|700px|Organizing Alarms]] | ||
Line 37: | Line 37: | ||
It is also possible to add or delete alarms in the system. | It is also possible to add or delete alarms in the system. | ||
− | * | + | * Click the '''Add''' or '''Delete''' icon (top right) to add or delete an alarm. |
− | == Advanced | + | == Advanced Options == |
* Check the '''Use Default Parameters''' box to use default values for the parameters | * Check the '''Use Default Parameters''' box to use default values for the parameters | ||
− | * Check the '''Override pre-selected Zones''' box to use dynamic destinations. This will also override static destination list if defined. | + | * Check the '''Override pre-selected Zones by Zone Select''' box to use dynamic destinations. |
+ | - This will also override the static destination list if defined. | ||
'''<u>On Busy</u>'''<br> | '''<u>On Busy</u>'''<br> | ||
Line 48: | Line 49: | ||
: '''Go Partial''' - Run the broadcast now on free zones | : '''Go Partial''' - Run the broadcast now on free zones | ||
: '''Queue''' - Put the broadcast in queue and run when all zones are free | : '''Queue''' - Put the broadcast in queue and run when all zones are free | ||
− | |||
If no value is chosen, a default value is used. | If no value is chosen, a default value is used. |
Revision as of 13:18, 13 December 2016
Alarm Control is used to control the alarm generator. This concerns programmed alarms that can be used if a control output should toggle in accordance with the actual alarm.
- Drag-and-drop: Input Action > Alarm Control to:
Amplifier > Control Inputs > CI_1-CI_6 > on_action/off_action
or
Access Panels > Programmable Keys > p1-px > press_action/release_action
Source
The Alarm source that should be controlled.
Activation
Start, Stop or Toggle the Alarm.
Destination
Zones in which the Alarm will be broadcast. Alarm broadcasts usually go to all zones. This field can be left blank if access panel keys are used for zone selection.
Priority
In this example for General Alarm, the priority should be set high, with only Emergency PA as a higher priority in the system. The highest priority is 1 and the lowest is 100.
Organizing Alarms
Alarms can be organized and renamed using the Exigo Management Tool (EMT).
Renaming Alarms
For easy identification of an alarm, they can be renamed to a more logical name.
To rename Alarms:
- Select System > Alarms
- Select the Alarm you want to rename
- Type in a new name in the Name field and click Done
It is also possible to add or delete alarms in the system.
- Click the Add or Delete icon (top right) to add or delete an alarm.
Advanced Options
- Check the Use Default Parameters box to use default values for the parameters
- Check the Override pre-selected Zones by Zone Select box to use dynamic destinations.
- This will also override the static destination list if defined.
On Busy
When one or more destination zones are busy with higher priority broadcasts, the following options are available:
- Reject - Reject the broadcast
- Go Partial - Run the broadcast now on free zones
- Queue - Put the broadcast in queue and run when all zones are free
If no value is chosen, a default value is used.
- For input actions Program Activation, Message, the default value is Go Partial.
- For input action Live Speech, the default value is Reject.
On Interrupt
When a broadcast is interrupted by a higher priority broadcast, the following options are available:
- Cancel - Cancel the broadcast
- Mute - Mute the broadcast in interrupted zones while a higher priority broadcast is running
- For input actions such as Program Activation, Message, Live Speech, the default value is Mute.