Difference between revisions of "Control Outputs"
Jump to navigation
Jump to search
(Tag: Visual edit) |
(Tag: Visual edit) |
||
Line 18: | Line 18: | ||
== Control Outputs - Connections == | == Control Outputs - Connections == | ||
− | '''Connections on Rack | + | '''Connections on Rack Devices:''' |
[[File:Control_outputs_1.JPG|thumb|left|700px|Rack Devices]] | [[File:Control_outputs_1.JPG|thumb|left|700px|Rack Devices]] | ||
<br style="clear:both;" /> | <br style="clear:both;" /> | ||
Line 33: | Line 33: | ||
* In '''Components''' view open '''Output Actions''' | * In '''Components''' view open '''Output Actions''' | ||
* In '''System''', identify the device and expand to '''Control Outputs''' | * In '''System''', identify the device and expand to '''Control Outputs''' | ||
− | * Drag the desired '''Output Action''' to the '''Control Output''' | + | * Drag the desired '''Output Action''' to the '''Control Output''' > '''CO_x''' |
* Set relevant parameters in the dialog box that appears | * Set relevant parameters in the dialog box that appears | ||
== Limitations == | == Limitations == | ||
− | === ENA | + | === ENA Amplifiers === |
− | Relay | + | Relay Outputs: |
* Max 24 VDC, 60 W | * Max 24 VDC, 60 W | ||
* Max 250 VAC, 125 VA | * Max 250 VAC, 125 VA | ||
− | 24 VDC | + | 24 VDC Outputs: |
* 24 VDC, ±10%, 200 mA | * 24 VDC, ±10%, 200 mA | ||
=== Access Panels === | === Access Panels === | ||
− | Relay | + | Relay Outputs: 2 (250VAC/200VDC, 2A, 60W) |
[[Category:3rd party integration]] | [[Category:3rd party integration]] | ||
[[Category:Output Actions]] | [[Category:Output Actions]] |
Revision as of 16:28, 12 December 2016
This article describes the control outputs in the Exigo system in general.
- Control Inputs are available on:
- System Controller
- Amplifiers
- Access Panels (Not Ex panels)
- Rack Devices (Controllers/Amplifiers):
- 6 NO/NC relays and 24V DC outputs (200 mA)
- Access Panels:
- 2 NO/NC relays, and 6 digital outputs
- Outputs are used e.g. for:
- Visual Call / Audio Indication
- Local Mute of nearby loudspeakers
- Volume Override
Contents
Control Outputs - Connections
Connections on Rack Devices:
Connections on Access Panels:
Configuration
Configuration of Control Outputs are done in EMT:
- In Components view open Output Actions
- In System, identify the device and expand to Control Outputs
- Drag the desired Output Action to the Control Output > CO_x
- Set relevant parameters in the dialog box that appears
Limitations
ENA Amplifiers
Relay Outputs:
- Max 24 VDC, 60 W
- Max 250 VAC, 125 VA
24 VDC Outputs:
- 24 VDC, ±10%, 200 mA
Access Panels
Relay Outputs: 2 (250VAC/200VDC, 2A, 60W)