Difference between revisions of "Control Outputs"
Jump to navigation
Jump to search
(Tag: Visual edit) |
(→Configuration) |
||
Line 35: | Line 35: | ||
* Drag the desired '''Output Action''' to '''Control Output''' > '''CO_x''' | * Drag the desired '''Output Action''' to '''Control Output''' > '''CO_x''' | ||
* Set relevant parameters in the dialog box that appears | * Set relevant parameters in the dialog box that appears | ||
+ | |||
+ | ===Advanced Options:=== | ||
+ | ::'''Limit High Not OK:''' When the Control Output is cleared, and feedback voltage is at or above this value, the output is considered fed with alien voltage. | ||
+ | |||
+ | ::'''Limit Low OK:''' When the Control Output is set, and feedback voltage is above this value, the output is considered active OK. | ||
+ | |||
+ | ::'''On Lost Connection:''' Sets the state on the control output when connection is lost. Available Settings: '''Idle State, No Change, Open, Closed'''. | ||
== Limitations == | == Limitations == |
Revision as of 14:40, 16 April 2018
This article describes the control outputs in the Exigo system in general.
- Control Outputs are available on:
- System Controller
- Amplifiers
- Access Panels (Not Ex panels)
- Rack Devices (Controllers/Amplifiers):
- 6 NO/NC relays and 24V DC outputs (200 mA)
- Access Panels:
- 2 NO/NC relays, and 6 digital outputs
- Outputs are used, e.g. for:
- Visual Call / Audio Indication
- Local Mute of nearby loudspeakers
- Volume Override
Contents
Control Outputs - Connections
Connections on Rack Devices:
Connections on Access Panels:
Configuration
Configuration of Control Outputs are done in EMT:
- In Components view open Output Actions
- In System, identify the device and expand to Control Outputs
- Drag the desired Output Action to Control Output > CO_x
- Set relevant parameters in the dialog box that appears
Advanced Options:
- Limit High Not OK: When the Control Output is cleared, and feedback voltage is at or above this value, the output is considered fed with alien voltage.
- Limit Low OK: When the Control Output is set, and feedback voltage is above this value, the output is considered active OK.
- On Lost Connection: Sets the state on the control output when connection is lost. Available Settings: Idle State, No Change, Open, Closed.
Limitations
ENA Amplifiers
Relay Outputs:
- Max 24 VDC, 60 W
- Max 250 VAC, 125 VA
24 VDC Outputs:
- 24 VDC, ±10%, 200 mA
Access Panels
Relay Outputs: 2 (250VAC/200VDC, 2A, 60W)