Release Note Exigo 1.6
Contents
- 1 Exigo 1.6.3.1
- 1.1 Software included in EXIGO-1.6.3.1.zip
- 1.2 Bugfixes and improvements
- 1.2.1 MTN-3784 Increased timeout for backed up amplifiers detect
- 1.2.2 MTN-3767 EMT: Control backup amplifiers
- 1.2.3 MTN-3720 EMT Monitoring: Destinations in Audio Activity
- 1.2.4 MTN-3702 EMT: Copy to paired device now works
- 1.2.5 MTN-3665 EMT: Added scrollbar to AVC section (Zone Editor) and Device Configuration List
- 1.2.6 MTN-3626 Kit devices will now read their IP address
- 1.2.7 MTN-3612 EMT Monitoring: Queue in Audio Activity monitoring
- 1.2.8 MTN-3608 EMT: IP-LCM Control Input Monitoring removal
- 1.2.9 MTN-3522 EMT: IP-LCM inherit in A/B System
- 1.2.10 MTN-3507 Control inputs on IP-LCM, Kits and Amplifiers now de-escalate correctly after escalated recall
- 1.2.11 MTN-3474 EMT: Delay for missing device possible to set on flowire
- 1.2.12 MTN-3468 EMT Monitoring: Showing fault list on first connect
- 1.2.13 MTN-3218 EMT: Alarm with frequencies that are not within 50Hz to 4kHz range can not be verified
- 1.2.14 MTN-3041 EMT: Global snmp fixes
- 1.2.15 MTN-2936 Missing device report can be sent as SNMP trap
- 1.2.16 MTN-1956 External fault on panel
- 1.2.17 MTN-1919 Fault LED will no longer stay lit after LED/system testing
- 1.2.18 EPB-492 EMT: Corrected resolution of delay on output from 10 ms to 20 ms
- 1.2.19 EPB-484 SLM audio level values are now reported correctly
- 1.2.20 EPB-470 GPO's can now be tested from IP-LCM's webpage
- 1.2.21 EPB-452 CO - fault indication on unacknowledged fault
- 1.3 Known Issues
- 2 Exigo 1.6.3.0
- 2.1 Software included in EXIGO-1.6.3.0.zip
- 2.2 New Features and Enhancements
- 2.3 Fixed Issues
- 2.3.1 MTN-3673 Correct SLM channel in LET communication is now used
- 2.3.2 MTN-3647 Control input is now updated on startup for ENA2x00-AC2
- 2.3.3 MTN-3627 IP-LCM will not end up in a reboot loop any-more when assigning actions to Control I/O
- 2.3.4 MTN-3623 Current state of GPIO is now reported for IP-LCM
- 2.3.5 MTN-3610 If logging is enabled, it will now stay enabled after reboot as well
- 2.3.6 MTN-3609 Status of I/O is now shown on webpage for IP-LCM
- 2.3.7 MTN-3607 SSH keys are kept on upgrade
- 2.3.8 MTN-3461 Cooling fan fault now reports speed and affected fans on ENA2x00-AC2
- 2.3.9 MTN-3351 A time limited alarm should now time out even if they are queued by a higher priority interrupting call
- 2.3.10 MTN-3331 Removed option to report ground fault as warning
- 2.3.11 MTN-3233 System faults and SNMP trap faults are now generated when EBMDR is disconnected
- 2.3.12 MTN-3210 ESC now has alarm LED check on priority
- 2.4 Known Issues
Exigo 1.6.3.1
Release status: Official, available Release date: 26.04.2022 Software collection file: EXIGO-1.6.3.1.zip
Software included in EXIGO-1.6.3.1.zip
Product | Version | Product description |
VSF-Turbine | VSFT-PA.6.5.3.3 | Firmware for the following devices: ESC1 (Secondary System Controller), ENA2X00, ENA2X00-AC2, ECPIR-X, EAPIR-8, EAPFX-X, EAPII-X, TKIS-2, TKIE-2, IP-LCM. |
AlphaSys Firmware | 13.0.3.15 | Firmware for the ESC1 (Primary System Controller/AMC-IP board) alpha-sys_13.0.3.15.apkg, bsp_32.2.3.6.apkg |
VS-EMT Exigo Management Tools | EMT-1.7.3.1 | Configuration tool, installed on a Windows PC |
VS-DEVICE-MIB | 201806190000Z | SNMP MIB for Exigo EXI-Devices, for upload in 3rd-party SNMP based monitoring tools |
Bugfixes and improvements
MTN-3784 Increased timeout for backed up amplifiers detect
Backup amplifier will wait longer after boot for backed up amplifiers to get ready to compensate for network equipment slow startup times.
MTN-3767 EMT: Control backup amplifiers
Take over and release amplifier options for ENA2200-AC2 and ENA2400-AC2 are now available.
MTN-3720 EMT Monitoring: Destinations in Audio Activity
Previously, only zones were available as destination for Audio Activity. Now, same destinations as for controller (ESC) are available in EMT Monitoring.
MTN-3702 EMT: Copy to paired device now works
Copy to paired device in EMT did not include all settings. This is now fixed.
MTN-3665 EMT: Added scrollbar to AVC section (Zone Editor) and Device Configuration List
MTN-3626 Kit devices will now read their IP address
MTN-3612 EMT Monitoring: Queue in Audio Activity monitoring
Queued call activity was not always appearing in monitoring list. Solved.
MTN-3608 EMT: IP-LCM Control Input Monitoring removal
IP-LCM is not capable of monitoring control inputs. Selection removed in EMT.
MTN-3522 EMT: IP-LCM inherit in A/B System
IP-LCM B not inheriting when configured to inherit. Now working.
MTN-3507 Control inputs on IP-LCM, Kits and Amplifiers now de-escalate correctly after escalated recall
MTN-3474 EMT: Delay for missing device possible to set on flowire
Flowires were not included when setting global delay time for missing device registration. Now working, and delay option can be set on each flowire individually.
MTN-3468 EMT Monitoring: Showing fault list on first connect
On first connect, EMT did not always bring up the fault list. Working fine now.
MTN-3218 EMT: Alarm with frequencies that are not within 50Hz to 4kHz range can not be verified
MTN-3041 EMT: Global snmp fixes
Two issues fixed:
- Bad indication for global snmp settings on device when selecting global.
- During project reload, devices were not loading snmp settings properly when configured to global.
MTN-2936 Missing device report can be sent as SNMP trap
System controller can send missing device report or PSC down as SNMP trap.
SNMP trap, Missing Device
Added snmp trap "Missing Device" for ESC1.
MTN-1956 External fault on panel
When multiple buttons were configured with same external fault ID, and user pressed off one of the buttons, system turned off all alarm LEDs with same fault ID even with other buttons active. Now working as it should.
MTN-1919 Fault LED will no longer stay lit after LED/system testing
EPB-492 EMT: Corrected resolution of delay on output from 10 ms to 20 ms
EPB-484 SLM audio level values are now reported correctly
EPB-470 GPO's can now be tested from IP-LCM's webpage
EPB-452 CO - fault indication on unacknowledged fault
From EMT, user may activate GPO to trigger only at unacknowledged faults in the fault state selection.
Known Issues
MTN-2911 Zone selection - deselect after timeout issue
Configuration with <Enable Timeout> for deselecting zone selection is not working
Exigo 1.6.3.0
Release status: Official, available Release date: 28.01.2022 Software collection file: EXIGO-1.6.3.0.zip
Software included in EXIGO-1.6.3.0.zip
Product | Version | Product description |
VSF-Turbine | VSFT-PA.6.5.3.0 | Firmware for the following devices: ESC1 (Secondary System Controller), ENA2100, ENA2200 AC2, ENA2400 AC2, ECPIR-3P, ECPIR-P, EAPIR-8, EAPFX-1, EAPFX-6, EAPII-1, EAPII-6, TKIS-2, TKIE-2, IP-LCM. |
AlphaSys Firmware | 13.0.3.14 | Firmware for the ESC1 (Primary System Controller/AMC-IP board) alpha-sys_13.0.3.14.apkg, bsp_32.2.3.6.apkg |
VS-EMT Exigo Management Tools | EMT-1.7.3.0 | Configuration tool, installed on a Windows PC |
VS-DEVICE-MIB | 201806190000Z | SNMP MIB for Exigo EXI-Devices, for upload in 3rd-party SNMP based monitoring tools |
New Features and Enhancements
MTN-3442 20 sec of audio delay supported per output audio channel
Each audio output channel can support up to 20 seconds of audio delay. Delay can be configured in 10 ms steps. Audio that is delayed will play for the rest of the delay duration even if the audio activity (live speech, alarm, message...) is stopped.
Limitations:
- Volume reduction and override are not supported on delayed audio channels
- VU meters on ENA2200/2400 display do not follow delayed audio
- Backup amplifier doesn't support delay
- Hardware Bypass audio on ENA2100AC and ENA2x00-AC2 does not support delay
MTN-3440 Override playback delay if only one zone is addressed in active call
This will disable channel delay for all lines in specific zone, if override channel delay is enabled on that zone and that zone is only zone in active call (live speech, message, alarm...). Multiple calls can be active on the system, just the ones with single zone as destination will have playback delay disabled for the duration of the call. After single zone call is ended, delay will be restarted on the affected lines.
EPB-395 Control Output status from Web
ENA2x00-AC2 and ENA2100: Real control output status added to the web in I/O Monitoring section.
EPB-243 Analog 1670 amplifier available in EMT
Added feature to enable 1670 Amplifiers to be an integrated part of EMT using a TKIS-2 Kit as a gateway.
Fixed Issues
MTN-3673 Correct SLM channel in LET communication is now used
The status in both channels are now correctly reported.
MTN-3647 Control input is now updated on startup for ENA2x00-AC2
MTN-3627 IP-LCM will not end up in a reboot loop any-more when assigning actions to Control I/O
MTN-3623 Current state of GPIO is now reported for IP-LCM
MTN-3610 If logging is enabled, it will now stay enabled after reboot as well
MTN-3609 Status of I/O is now shown on webpage for IP-LCM
MTN-3607 SSH keys are kept on upgrade
MTN-3461 Cooling fan fault now reports speed and affected fans on ENA2x00-AC2
- Cooling fan too slow or too fast now reports correct error message
- PSU voltage monitoring and fault reporting now available for ENA2x00-AC2
MTN-3351 A time limited alarm should now time out even if they are queued by a higher priority interrupting call
MTN-3331 Removed option to report ground fault as warning
Ground faults will always be reported as faults.
MTN-3233 System faults and SNMP trap faults are now generated when EBMDR is disconnected
MTN-3210 ESC now has alarm LED check on priority
Known Issues
MTN-2911 Zone selection - deselect after timeout issue
Configuration with <Enable Timeout> for deselecting zone selection is not working