Difference between revisions of "TKIE-2"
(→TKIE-2 Overview) |
|||
(14 intermediate revisions by the same user not shown) | |||
Line 3: | Line 3: | ||
The TKIE-2 is the extended version of our Turbine Kit range. It is the same Kit as TKIE-1 but with a metal enclosure suitable for DIN-rail mounting. <br> | The TKIE-2 is the extended version of our Turbine Kit range. It is the same Kit as TKIE-1 but with a metal enclosure suitable for DIN-rail mounting. <br> | ||
− | It offers the same high quality audio as the TKIS-x kit, but adds to the feature list with an extra RJ45 port for dual Ethernet connectivity, dual relays, and a header for easy connection of audio accessories. For high-power applications, the TKIE-2 may be complemented with the TA-10 Relay Module which offers 2 DPDT relays suited for high-voltage/high-current applications. | + | It offers the same high quality audio as the TKIS-x kit, but adds to the feature list with an extra RJ45 port for dual Ethernet connectivity, dual relays, and a header for easy connection of audio accessories. For high-power applications, the TKIE-2 may be complemented with the [[TA-10]] Relay Module which offers 2 DPDT relays suited for high-voltage/high-current applications. |
* IP station kit with extended functionality | * IP station kit with extended functionality | ||
Line 11: | Line 11: | ||
* Line-in/Line-out connectivity for connection to audio devices | * Line-in/Line-out connectivity for connection to audio devices | ||
* Header for connecting audio accessories | * Header for connecting audio accessories | ||
− | * Possibility for connecting high-power relay module (TA-10) | + | * Possibility for connecting high-power relay module ([[TA-10]]) |
* High quality Turbine™ class output with 10W amplifier | * High quality Turbine™ class output with 10W amplifier | ||
* Full open duplex and digital noise reduction | * Full open duplex and digital noise reduction | ||
* Metal enclosure suitable for DIN-rail mounting | * Metal enclosure suitable for DIN-rail mounting | ||
− | == | + | == TKIE-2 Overview == |
− | + | [[File:TKIE 2 overview 1.png|left|600px]] | |
+ | <br style="clear:both;" /> | ||
+ | [[File:TKIE 2 overview 2.png|left|600px]] | ||
+ | <br style="clear:both;" /> | ||
+ | {| border="1" | ||
+ | | align="center" style="background:#ffd400;" width="50pt"| 1 || align="left" | Relay Inputs || align="left"| Programmable relay inputs (NO+NC+COM). Max: 250VAC/220VDC, 2A, 60W | ||
+ | |- | ||
+ | | align="center" style="background:#ffd400;" width="50pt"| 2 || align="left" | I/O interface || align="left"| Interface for control inputs, control outputs and analog audio | ||
+ | |- | ||
+ | | align="center" style="background:#ffd400;" width="50pt"| 3 || align="left" | External Audio || align="left"| Connection for microphone and optional external loudspeaker | ||
+ | |- | ||
+ | | align="center" style="background:#ffd400;" width="50pt"| 4 || align="left" | TA-10 Relay Interface || align="left"| Connects to TA-10 Relay Module for high-power switching applications | ||
+ | |- | ||
+ | | align="center" style="background:#ffd400;" width="50pt"| 5 || align="left" | Ethernet/PoE Port || align="left"| Ethernet connection with Power over Ethernet | ||
+ | |- | ||
+ | | align="center" style="background:#ffd400;" width="50pt"| 6 || align="left" | Secondary Power || align="left"| Connector for secondary local power | ||
+ | |- | ||
+ | | align="center" style="background:#ffd400;" width="50pt"| 7 || align="left" | Ethernet/PoE Port || align="left"| Ethernet connection with Power over Ethernet | ||
+ | |- | ||
+ | |} | ||
+ | <br> | ||
== Connections == | == Connections == | ||
Line 36: | Line 56: | ||
|} | |} | ||
− | + | {{Note}} Use cables crimped with ferrules for terminal block connectors | |
*If connected to two PoE-capable switches, only one of the ports will negotiate PoE; hence this is not a good solution for | *If connected to two PoE-capable switches, only one of the ports will negotiate PoE; hence this is not a good solution for | ||
Line 78: | Line 98: | ||
:Pin 6 NC relay 2 | :Pin 6 NC relay 2 | ||
− | + | {{Note}} Relay 1 is configured as output 7, and Relay 2 is configured as output 8! | |
'''P6''' Loudspeaker & Electret microphone | '''P6''' Loudspeaker & Electret microphone | ||
Line 87: | Line 107: | ||
'''J2''' [[TA-10|Turbine Relay Module - TA-10]] | '''J2''' [[TA-10|Turbine Relay Module - TA-10]] | ||
− | + | {{Note}} Relay 3 is configured as output 9, and Relay 4 is configured as output 10! | |
'''J8''' Headset/Handset connector | '''J8''' Headset/Handset connector | ||
Line 102: | Line 122: | ||
+ | == Restore Factory Defaults == | ||
+ | See article: [https://wiki.zenitel.com/wiki/TKIE_Restore_Factory_Defaults Restore Factory Default] | ||
+ | |||
+ | == Dimensions == | ||
+ | [[File:TKIE-2 dimensions.PNG|left|upright=2.0|700px|ECPIR-P dimensions]] | ||
+ | <br style="clear:both;" /> | ||
+ | |||
+ | == Accessories == | ||
+ | |||
+ | {|{{SimpleTable}} | ||
+ | |- | ||
+ | !style="background:#FFFFFF;" width="200"|[[File:TA-10.jpg|100px|link=TA-10]] | ||
+ | |- | ||
+ | |style="text-align:center;"|[[TA-10]] | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | == Additional Documentation == | ||
+ | For more documentation, please visit the Zenitel web page: https://www.zenitel.com/product/tkie-2 | ||
+ | |||
+ | == Availability == | ||
+ | This device is supported from Exigo 1.3 and newer. | ||
[[Category:Hardware]] | [[Category:Hardware]] | ||
+ | [[Category:Kits]] |
Latest revision as of 15:47, 31 January 2019
Voip Intercom Module
The TKIE-2 is the extended version of our Turbine Kit range. It is the same Kit as TKIE-1 but with a metal enclosure suitable for DIN-rail mounting.
It offers the same high quality audio as the TKIS-x kit, but adds to the feature list with an extra RJ45 port for dual Ethernet connectivity, dual relays, and a header for easy connection of audio accessories. For high-power applications, the TKIE-2 may be complemented with the TA-10 Relay Module which offers 2 DPDT relays suited for high-voltage/high-current applications.
- IP station kit with extended functionality
- Dual RJ45 for Ethernet connectivity (with switch)
- Dual relays (DPDT)
- 6 configurable I/Os (input, output or LED-driving)
- Line-in/Line-out connectivity for connection to audio devices
- Header for connecting audio accessories
- Possibility for connecting high-power relay module (TA-10)
- High quality Turbine™ class output with 10W amplifier
- Full open duplex and digital noise reduction
- Metal enclosure suitable for DIN-rail mounting
Contents
TKIE-2 Overview
1 | Relay Inputs | Programmable relay inputs (NO+NC+COM). Max: 250VAC/220VDC, 2A, 60W |
2 | I/O interface | Interface for control inputs, control outputs and analog audio |
3 | External Audio | Connection for microphone and optional external loudspeaker |
4 | TA-10 Relay Interface | Connects to TA-10 Relay Module for high-power switching applications |
5 | Ethernet/PoE Port | Ethernet connection with Power over Ethernet |
6 | Secondary Power | Connector for secondary local power |
7 | Ethernet/PoE Port | Ethernet connection with Power over Ethernet |
Connections
There are two RJ-45 ports located on the TKIE-2 that are used for PoE/LAN Ethernet connection.
There are 6 I/O connection options for the TKIE-2. These connections are used as digital input (eg. form a closing contact), digital output (5V), or LED driving (20mA max) for connecting sensors, indicators or integration to other systems.
Ethernet/Power | The TKIE-2 supports Power over Ethernet (PoE, IEEE 802.3 a-f) where power can be drawn from either the spare line or signal line.* |
Secondary Power | If PoE in not available, the TKIE-2 can be powered from a 24-48 VDC local power supply.** |
Relays | There are two Double Throw relay contacts with 60W switching power. COM, NO, NC contacts are provided. |
Input/Output | 6 I/Os are available. Each I/O can be configured as either input, output, or LED driver. |
Audio Line Out | A balanced 600 ohm audio line out with induction loop signal |
Use cables crimped with ferrules for terminal block connectors
*If connected to two PoE-capable switches, only one of the ports will negotiate PoE; hence this is not a good solution for power redundancy (switch failure might lead to a reboot). Instead a “dumb” PoE injector (spare-pair power) should be used for the two Ethernet ports or a local 24 VDC local power backup.
**If used together with PoE the station can be powered by 24 VDC as a local power backup.
- When the TKIE-2 is connected to the network, its IP address is automatically obtained from a DHCP server or an IP address in the range 169.254.x.x will be assigned.
P1&P2 RJ45 PoE port for 10/100 Mbit Ethernet connection.
- The station can be powered from this port if the line supports Power over Ethernet (PoE).
P3 Secondary Power; 24-48VDC
P4 10-pin plug-on terminal for external connections.
- Pin 1 5.3V
- Pin 2 GND
- Pin 3 Button Input or LED Driver
- Pin 4 Button Input or LED Driver
- Pin 5 Button Input or LED Driver
- Pin 6 Button Input or LED Driver
- Pin 7 Button Input or LED Driver
- Pin 8 Button Input or LED Driver
- Pin 9 600 ohm balanced line out +
- Pin 10 600 ohm balanced line out -1
P5 6-pin plug-on terminal for external connections.
- Pin 1 COM relay 1
- Pin 2 NO relay 1
- Pin 3 NC relay 1
- Pin 4 COM relay 2
- Pin 5 NO relay 2
- Pin 6 NC relay 2
Relay 1 is configured as output 7, and Relay 2 is configured as output 8!
P6 Loudspeaker & Electret microphone
- Pin 1 10W Speaker amplifier +
- Pin 2 10W Speaker amplifier -
- Pin 3 Electret Microphone +
- Pin 4 Electret Microphone -
J2 Turbine Relay Module - TA-10
Relay 3 is configured as output 9, and Relay 4 is configured as output 10!
J8 Headset/Handset connector
- Pin 1 Offhook
- Pin 2 GND
- Pin 3 PTT
- Pin 4 Handset Mic Positive
- Pin 5 Handset Mic Negative
- Pin 6 Headphone Positive
- Pin 7 Headphone Negative
- Pin 8 Line In Positive
- Pin 9 Line In Negative
Restore Factory Defaults
See article: Restore Factory Default
Dimensions
Accessories
TA-10 |
Additional Documentation
For more documentation, please visit the Zenitel web page: https://www.zenitel.com/product/tkie-2
Availability
This device is supported from Exigo 1.3 and newer.