Difference between revisions of "Recall, Control"

From exigoWiki
Jump to navigation Jump to search
Line 34: Line 34:
  
 
'''<u>Volume</u>'''  
 
'''<u>Volume</u>'''  
Volume offset. Volume range is from -100 to 0 decibels.  
+
Volume offset. Volume range is from -100 to 0 decibels.
** '''Override pre-selected Zones''' - Use dynamic Destinations. This will also override the static destination list if defined.
+
* '''Override pre-selected Zones''' - Use dynamic Destinations. This will also override the static destination list if defined.
  
 
'''<u>On Busy</u>'''   
 
'''<u>On Busy</u>'''   
 
When one or more destination zones are busy with higher priority broadcasts, the following options are available:
 
When one or more destination zones are busy with higher priority broadcasts, the following options are available:
** '''Reject''' - Reject the broadcast  
+
* '''Reject''' - Reject the broadcast  
** '''Go Partial''' - Run the broadcast now on free zones  
+
* '''Go Partial''' - Run the broadcast now on free zones  
** '''Queue''' - Put the broadcast in queue and run when all zones are free  
+
* '''Queue''' - Put the broadcast in queue and run when all zones are free  
** '''Split Queue''' - If the source is a stored message, queue the broadcast per zone
+
* '''Split Queue''' - If the source is a stored message, queue the broadcast per zone
  
 
If no value is chosen, a default value is used.
 
If no value is chosen, a default value is used.
Line 52: Line 52:
 
'''Cancel''' - Cancel the broadcast  
 
'''Cancel''' - Cancel the broadcast  
 
'''Mute''' - Mute the broadcast in interrupted zones and queue it while a higher priority broadcast is running
 
'''Mute''' - Mute the broadcast in interrupted zones and queue it while a higher priority broadcast is running
** For input actions such as Audio Program Control, Message Control, Live Speech, the default value is Mute.
+
* For input actions such as Audio Program Control, Message Control, Live Speech, the default value is Mute.
  
 
'''<u>Release Delay</u>'''  
 
'''<u>Release Delay</u>'''  

Revision as of 15:32, 20 June 2016

Recall, Control is used to control the playback of recall recorded messages. It can also be used to control recall messages on other devices, but are mostly used on access panels.

Amplifier -> Control Inputs -> CI -> CI_1-CI_6 -> on_action/off_action

or

Access Panel -> Programmable Keys -> Key -> p1-px -> press_action/release_action


Recall Control 1.png


Activation Start, Stop or Toggle the broadcast.

Destination The Zone(s) that will receive the broadcast. This may be left blank if access panel keys are used for zone selection.

Message Source The device on which the recorded message is stored and played back - on panel devices it will default to Local Device. Local Device cannot be used from Controllers, Amplifiers and Kits.

Repetitions The number of times the message is played back. Check the Loop box for continuous playback.

Priority The priority of the broadcast. Check the Replace box to make this broadcast replace other broadcasts with the same priority. If the box is not checked, broadcasts with the same priority will be shown as busy.

Chime The chime sound that will be played before the broadcast starts.

Advanced options

  • Check the Use Default Parameters box to use default values for the parameters

Volume Volume offset. Volume range is from -100 to 0 decibels.

  • Override pre-selected Zones - Use dynamic Destinations. This will also override the static destination list if defined.

On Busy When one or more destination zones are busy with higher priority broadcasts, the following options are available:

  • Reject - Reject the broadcast
  • Go Partial - Run the broadcast now on free zones
  • Queue - Put the broadcast in queue and run when all zones are free
  • Split Queue - If the source is a stored message, queue the broadcast per zone

If no value is chosen, a default value is used. For input actions Audio Program Control, Message Control, the default value is Go Partial. For input action Live Speech, the default value is Reject.

On Interrupt When a broadcast is interrupted by a higher priority broadcast, the following options are available: Cancel - Cancel the broadcast Mute - Mute the broadcast in interrupted zones and queue it while a higher priority broadcast is running

  • For input actions such as Audio Program Control, Message Control, Live Speech, the default value is Mute.

Release Delay Time in seconds before the zones and resources are released after the broadcast has stopped. Any Control Output that triggers on this broadcast will then be activated.