Difference between revisions of "Factory Default"

From exigoWiki
Jump to navigation Jump to search
Line 25: Line 25:
  
 
There is two ways to do a factory default:
 
There is two ways to do a factory default:
* '''Factory Reset''' - This resets the configuration data. IP settings are kept.
+
* '''Factory Reset''' - This resets the configuration data. The SSC gets default IP address (169.254.1.100).
* '''Factory Reset with DHCP'''  
+
* '''Factory Reset with DHCP''' - This resets the configuration data. The station is set to receive IP from DHCP.
  
 
It is also possible to do a Factory default from the GUI on the controller.
 
It is also possible to do a Factory default from the GUI on the controller.
  
In the GUI go to Sub-Menu -> Restart device sub-menu
+
In the GUI go to '''Service''' -> '''Restart Device'''
  
 
[[File:Factory default 3.png|thumb|left|500px|ESC-1 - GUI]]
 
[[File:Factory default 3.png|thumb|left|500px|ESC-1 - GUI]]

Revision as of 07:49, 25 October 2016

This article describes how to set the different Exigo devices back to factory default.
If you encounter problems with a system a factory default might help solving the problem.

Factory Default on ESC-1 System Controller

The ESC-1 consists of Primary System Controller and Secondary System Controller.

Primary System Controller

To set the Primary System Controller (AMC-IP board) to factory default: In the web browser go to System Maintenance -> System Recovery

AMC-IP - Factory Default


There is two ways to do a factory default:

  • Load Factory Defaults - This resets the configuration data. IP settings are kept.
  • Clean & Factory Default - This resets the configuration data. It also remove license, SysLog and Backup files. Removes Exigo mode. IP settings are kept.

Secondary System Controller

To set the Secondary System Controller to factory default: In the web browser go to Station Administration -> Reboot

Secondary System Controller - Factory Default


There is two ways to do a factory default:

  • Factory Reset - This resets the configuration data. The SSC gets default IP address (169.254.1.100).
  • Factory Reset with DHCP - This resets the configuration data. The station is set to receive IP from DHCP.

It is also possible to do a Factory default from the GUI on the controller.

In the GUI go to Service -> Restart Device

ESC-1 - GUI