Difference between revisions of "Control Outputs"

From exigoWiki
Jump to navigation Jump to search
Line 1: Line 1:
[[File:Control Inputs 1.JPG|thumb|right|350px|Devices with Control Inputs available]]
+
[[File:Control Inputs 1.JPG|thumb|right|350px|Devices with Control Outputs available]]
 
This article describes the control outputs on Exigo in general. <br>
 
This article describes the control outputs on Exigo in general. <br>
 
*'''Control Inputs''' are available on:
 
*'''Control Inputs''' are available on:
Line 19: Line 19:
 
==Control Outputs - Connections==
 
==Control Outputs - Connections==
 
'''Connections on rack devises'''
 
'''Connections on rack devises'''
[[File:Control Inputs 2.JPG|thumb|left|700px|Rack devices]]
+
[[File:Control_outputs_1.JPG|thumb|left|700px|Rack devices]]
 
<br style="clear:both;" />
 
<br style="clear:both;" />
  

Revision as of 07:54, 9 August 2016

Devices with Control Outputs available

This article describes the control outputs on Exigo in general.

  • Control Inputs are available on:
    • System Controller
    • Amplifiers
    • Access Panels (Not EX panels)
  • Rack devices (Controllers/Amplifiers):
    • 6 NO/NC relays and 24V DC outputs (200 mA).
  • Access Panels:
    • 2 NO/NC relays, and 6 digital outputs.
  • Outputs are used e.g. for:
    • Visual Call/Audio Indication
    • Local mute of nearby loudspeakers
    • Volume override

Control Outputs - Connections

Connections on rack devises

Rack devices


Connections on access panels

Rack devices


Configuration

Configuration of Control Outputs are done in EMT:

Input 1 on amplifier starts «Fire Alarm» message in «Main Building»


  • In Components view open Input Actions
  • In System, identify the device and expand to Control Inputs
  • Drag the desired Input Action to the on_action or the off_action
  • Set relevant parameters in the dialog box that appears