Configuration of distribution of General Alarm and high priority live speech from Exigo to AlphaCom

From exigoWiki
Revision as of 10:16, 6 April 2017 by Gsorensen (talk | contribs) (AlphaPro)
Jump to navigation Jump to search

This article describes the configuration needed when distributing General Alarm and high priority live speech from Exigo to AlphaCom/ACM.

  • It is important that users of AlphaCom/ACM are not able to disconnect the Exigo PA call from the InterCom station.
  • All audio from Exigo to AlphaCom/ACM will be distributed with handset and volume override.

Configuration Example

Group number, program number, directory number and cos can of cause be changed to user request.


EMT

Exigo Description
AlphaCom Feature added as member of Zone "AlphaCom/ACM" 8075

Configuration in Exigo Management Toll (EMT):

  • Drag AlphaCom Feature to System -> Integration -> AlphaCom
AlphaCom Feature


  • Drag the configured AlphaCom Feature to the designated zone
AlphaCom Feature



AlphaPro

Overview of configuration in AlphaPro:

AlphaCom Description Info
Station group used in AlphaCom to include stations receiving EXIGO calls Group 10 NB! The group feature/directory number is not used. Only the list of group members
Program Channel used for audio distribution Program 7, Flags set: Program over Conversation, Volume/Handset Override NB! The program feature/directory number is not used.
NB! The program channel must not be related to physical hardware. (AGA/APC)
Feature for triggering audio to ACM stations inn group 10 "8075" "Exigo Call"
Feature 118, Param1 = 7 , Param2 = 10
Will start Program 7 to all members of group 10

Availability