Configuration of distribution of General Alarm and high priority live speech from Exigo to AlphaCom
Jump to navigation
Jump to search
This article describes the configuration needed when distributing General Alarm and high priority live speech from Exigo to AlphaCom/ACM.
- It is important that users of AlphaCom/ACM are not able to disconnect the Exigo PA call from the InterCom station.
- All audio from Exigo to AlphaCom/ACM will be distributed with handset and volume override.
Configuration Example
Group number, program number, directory number and cos can of cause be changed to user request.
EMT
Exigo | Description |
AlphaCom Feature added as member of Zone "AlphaCom/ACM" | 8075 |
Configuration in Exigo Management Toll (EMT):
- Drag AlphaCom Feature to System -> Integration -> AlphaCom
- Drag the configured AlphaCom Feature to the designated zone
AlphaPro
AlphaCom | Description | Info |
Station group used in AlphaCom to include stations receiving EXIGO calls | Group 10 | NB! The group feature/directory number is not used. Only the list of group members |
Program Channel used for audio distribution | Program 7, Flags set: Program over Conversation, Volume/Handset Override | NB! The program feature/directory number is not used. NB! The program channel must not be related to physical hardware. (AGA/APC) |
Availability
This function is available from Exigo 1.3 and newer.