Control Outputs
Jump to navigation
Jump to search
This article describes the control outputs on Exigo in general.
- Control Inputs are available on:
- System Controller
- Amplifiers
- Access Panels (Not EX panels)
- Outputs are used e.g. for:
- Visual Call/Audio Indication
- Local mute of nearby loudspeakers
- Volume override
Control Outputs - Connections
Connections on rack devises
- Rack devices (Controllers/Amplifiers):
- 6 NO/NC relays and 24V DC outputs (200 mA).
Connections on access panels
- Access Panels:
- 2 NO/NC relays, and 6 digital outputs.
Configuration
Configuration of Control Outputs are done in EMT:
- In Components view open Input Actions
- In System, identify the device and expand to Control Inputs
- Drag the desired Input Action to the on_action or the off_action
- Set relevant parameters in the dialog box that appears