This article describes how to configure the IP settings in Exigo.
Initially all devices must be configured with:
- Own IP address
- IP Address of Primary System Controller
- ID number (Directory Number)
- Default Gateway
Creating a table with relevant information is considered good practice.
Primary System Controller
To set the IP address for the Primary System Controller:
- Open the front cover on the ESC1.
- Connect a PC to the service port (npe_eth0). This has 169.254.1.5 as default IP.
- Log on with a Web Browser (admin/alphaadmin).
- Navigate to System Configuration -> Interfaces:
- Set the desired IP Address of the Primary Controller (npe_eth1).
Secondary System Controller
To configure the IP setting for the Secondary System Controller:
- Connect a PC to either Eth1 or Eth2 on ESC1.
- Log on to SSC with a Web Browser.
- Navigate to Station Main -> Main Settings:
- Set IP address of the Primary System Controller.
- Set the Directory Number.
- Set the IP Address of the SSC.
- Set the default Gateway.
Exigo devices (Amplifiers, panels and kits)
To configure the IP setting for Exigo devices:
- Log on to the device with a Web Browser.
- Navigate to Station Main -> Main Settings:
- Set IP address of the Domain Controller.
- Set the Directory Number.
- Set the IP Address of the SSC.
- Set the default Gateway.