==Configuration==
 
==Configuration==
===VOlume Override on a specific Zone===
+
===Volume Override on a specific Zone===
Announcements, Alarms and Messages from any Source to Zone 1 should turn on the lamp/Control Output
+
When Zone 1 receives audio activity with Priority over 40 the control output will be open (idle state is Normally Closed).
  
#Drag '''Audio Activity''' to the desired Control Output.
+
#Drag '''Volume Override''' to the desired Control Output.
 
#Select '''Zone 1''' in '''Zone'''.
 
#Select '''Zone 1''' in '''Zone'''.
#Under '''Audio Type''' select '''Message''', '''Live Speech''' and '''Alarm'''.
+
#Under '''Minimum Priority''' select '''40'''.
 +
 
 +
[[File:Volume override 3.JPG|thumb|left|500px|Volume Override configuration]]
 +
<br style="clear:both;" />
 +
 
 +
As long as Zone 1 receives audio activity with Priority 40 or less, the control output is closed/active (idle state is Normally Closed).
 +
 
  
 
==Parameter details==
 
==Parameter details==

Revision as of 08:13, 15 August 2016

Volume Override in Zone 1

Control Outputs are configured by defining one or more actions to be triggered on an output event.

The Volume Override function is used to trigger the control output on Volume Override in the indicated zone(s).

Volume Override is used when the system has volume controllers that must be kept active. Locally, such volume controllers may be used for adjusting the volume in a corridor for instance. As long as the volume controller has current, the physical volume setting will apply. If there is no more current, it will be overridden and go into bypass mode (i.e. no effect).

Assigning Volume Override to a Control Output

To assign the function Audio Activity to an Control Output:

  1. In Components view, open Output Actions
  2. In System, identify the Controller or the Amplifier to be used, and expand to Device > Control Outputs.
  3. Drag Volume Override to the Control Output you want to use.
Assigning Volume Override to a Control Output


Configuration

Volume Override on a specific Zone

When Zone 1 receives audio activity with Priority over 40 the control output will be open (idle state is Normally Closed).

  1. Drag Volume Override to the desired Control Output.
  2. Select Zone 1 in Zone.
  3. Under Minimum Priority select 40.
Volume Override configuration


As long as Zone 1 receives audio activity with Priority 40 or less, the control output is closed/active (idle state is Normally Closed).