Difference between revisions of "Control Outputs"
Jump to navigation
Jump to search
Line 1: | Line 1: | ||
− | [[File:Control Inputs 1.JPG|thumb|right|350px|Devices with Control | + | [[File:Control Inputs 1.JPG|thumb|right|350px|Devices with Control Outputs available]] |
This article describes the control outputs on Exigo in general. <br> | This article describes the control outputs on Exigo in general. <br> | ||
*'''Control Inputs''' are available on: | *'''Control Inputs''' are available on: | ||
Line 19: | Line 19: | ||
==Control Outputs - Connections== | ==Control Outputs - Connections== | ||
'''Connections on rack devises''' | '''Connections on rack devises''' | ||
− | [[File: | + | [[File:Control_outputs_1.JPG|thumb|left|700px|Rack devices]] |
<br style="clear:both;" /> | <br style="clear:both;" /> | ||
Revision as of 06:54, 9 August 2016
This article describes the control outputs on Exigo in general.
- Control Inputs are available on:
- System Controller
- Amplifiers
- Access Panels (Not EX panels)
- Rack devices (Controllers/Amplifiers):
- 6 NO/NC relays and 24V DC outputs (200 mA).
- Access Panels:
- 2 NO/NC relays, and 6 digital outputs.
- Outputs are used e.g. for:
- Visual Call/Audio Indication
- Local mute of nearby loudspeakers
- Volume override
Control Outputs - Connections
Connections on rack devises
Connections on access panels
Configuration
Configuration of Control Outputs are done in EMT:
- In Components view open Input Actions
- In System, identify the device and expand to Control Inputs
- Drag the desired Input Action to the on_action or the off_action
- Set relevant parameters in the dialog box that appears