Difference between revisions of "EMT Getting Started"

From exigoWiki
Jump to navigation Jump to search
Line 3: Line 3:
  
 
This article describes how to use EMT to create and upload a new database.<br>
 
This article describes how to use EMT to create and upload a new database.<br>
Before uploading a complete new database it is recommended to do a factory default of the controller: <br>
+
Before uploading a complete new database, it is recommended to do a factory reset of the controller:  
Log on to the Primary System Controller and go to: '''System Maintenance''' -> '''System Recovery''' -> '''Load Factory Defaults'''  
+
* Log on to the Primary System Controller and go to: '''System Maintenance''' > '''System Recovery''' > '''Load Factory Defaults'''
 
 
 
To create and upload a database, do the following:
 
To create and upload a database, do the following:
 
# Create a New Database
 
# Create a New Database

Revision as of 10:56, 9 March 2017

Exigo Management Tool

This article describes how to use EMT to create and upload a new database.
Before uploading a complete new database, it is recommended to do a factory reset of the controller:

  • Log on to the Primary System Controller and go to: System Maintenance > System Recovery > Load Factory Defaults

To create and upload a database, do the following:

  1. Create a New Database
  2. Add Amplifiers
  3. Define Zones
  4. Add Access Panels
  5. Upload Database
EMT - Getting Started


Step 1. Create a New Database

In the navigation pane, select Projects view.

  • Click New and follow the instructions in the wizard
EMT - New Database wizard


All of the parameters in the wizard may be changed at a later stage.

Step 2. Add Amplifiers

  • In Components view open Devices view
File:EMT getting started 3.JPG
EMT - Adding Amplifier


  • Drag the Amplifier into System

Step 3. Define Zones

To add zones in the system:

  • Click the + Add Zone button


It is recommended to give the zones a logical name.

EMT - Adding and naming zones


To add amplifier outputs to the zone:

  • Either drag the whole Amplifier or the Amplifier output channel to the zone
EMT - Assigning amplifier output to a zone


Step 4. Add Access Panels

  • In Components view open Devices view
EMT - Adding and naming zones


  • Drag the desired Access Panel into System

To add functions to the access panel (for example Live Speech) see Live Speech.

Step 5. Upload Database

  • In the Navigation pane, select Projects view
EMT - Send - uploads the data base to ESC1


  • Click Send to upload the new configuration database to the Exigo system