This article describes how to use EMT to create and upload a new database.
Before uploading a complete new database, it is recommended to do a Clean & Factory Default of the controller:

  • Log on to the Primary System Controller and go to: System Maintenance > System Recovery > Load Factory Defaults

To create and upload a database in EMT, do the following:

  1. Create a New Database
  2. Add Amplifiers
  3. Define Zones
  4. Add Access Panels
  5. Upload Database
EMT - Getting Started


Step 1. Create a New Database

In the navigation pane:

  • Select Projects
  • Click New and follow the instructions in the wizard
EMT - New Database wizard


All of the parameters in the wizard may be changed at a later stage.

Step 2. Add Amplifiers

  • Select Components
  • Click Devices to open options
EMT - Adding Amplifier


  • Drag the desired Amplifier into System

Step 3. Define Zones

To add zones to the system:

  • Click the + Add Zone button


It is recommended to give the zones a logical name.

EMT - Adding and naming zones


To add amplifier outputs to the zone:

  • Either drag the whole Amplifier or the Amplifier output channel to the zone
EMT - Assigning amplifier output to a zone


Step 4. Add Access Panels

  • Select Components
  • Click Devices to open options
EMT - Adding and naming zones


  • Drag the desired Access Panel into System

To add functions to the access panel (for example Live Speech) see Live Speech.

Step 5. Upload Database

In the navigation pane:

  • Select Projects
EMT - Send - uploads the data base to ESC1


  • Click Send to upload the new configuration database to the Exigo system