Revision as of 11:09, 21 September 2016

Devices with Control Outputs available

This article describes the control outputs on Exigo in general.

  • Control Inputs are available on:
    • System Controller
    • Amplifiers
    • Access Panels (Not EX panels)
  • Rack Devices (Controllers/Amplifiers):
    • 6 NO/NC relays and 24V DC outputs (200 mA).
  • Access Panels:
    • 2 NO/NC relays, and 6 digital outputs.
  • Outputs are used e.g. for:
    • Visual Call/Audio Indication
    • Local mute of nearby loudspeakers
    • Volume override

Control Outputs - Connections

Connections on Rack Devises:

Rack Devices


Connections on Access Panels:

Access Panels


Configuration

Configuration of Control Outputs are done in EMT:

Assigning Audio Activity on Control Output 1


  • In Components view open Output Actions
  • In System, identify the device and expand to Control Outputs
  • Drag the desired Output Action to the Control Output
  • Set relevant parameters in the dialog box that appears