Difference between revisions of "Fault Indication Advanced"

From exigoWiki
Jump to navigation Jump to search
(Parameter details)
Line 27: Line 27:
 
'''Subscribe To:''' Options are Faults or Warnings.  
 
'''Subscribe To:''' Options are Faults or Warnings.  
  
=== Filter Parameters: ===
+
'''Filter Script:''' Here you type/paste in the script you need..
::'''Affected Devices:''' Trigger on faults that affect selected devices.
 
  
::'''Affected Zones:''' Trigger on faults that affect selected zones.
 
 
::'''Affected Lines:''' Trigger on faults that affect selected audio lines.
 
 
::'''Severity:''' Trigger on faults at selected levels.
 
 
::'''Fault State:''' Trigger on faults in selected state.
 
 
::'''System Message:''' Trigger on faults that have selected messages.
 
  
  

Revision as of 12:19, 9 September 2016

Visual indication of fault in the system

Control Outputs are configured by defining one or more actions to be triggered on an output event.

The Fault Indication Advanced function is used to trigger the control output with custom filter scripts.

This function can be useful if you have specific need that cannot be accomplished with Fault Indication.
To solve the needs a custom script can then be used.

Assigning Fault Indication Advanced to a Control Output

To assign the function Fault Indication Advanced to an Control Output:

  1. In Components view, open Output Actions
  2. In System, identify the Controller, the Amplifier or the Access Panel to be used, and expand to Device > Control Outputs.
  3. Drag Fault Indication Advanced to the Control Output you want to use.
Assigning Fault Indication Advanced function to a Control Output


Parameter details

Idle State: Sets the idle state for the output. The options are Normally Open or Normally Closed

Delay Activation: Delays control output activation for the stipulated number of seconds when triggered.

Reporting System: The system, i.e. System A, System B or System A and B, from which faults will be received (only available in A-B System projects).

Subscribe To: Options are Faults or Warnings.

Filter Script: Here you type/paste in the script you need..