Difference between revisions of "Fault Indication"

From exigoWiki
Jump to navigation Jump to search
(Assigning Fault Indication to a Control Output)
Line 1: Line 1:
[[File:Fault indication 1.JPG|thumb|right|350px|Visual indication of Audio Activity]]
+
[[File:Fault indication 1.JPG|thumb|right|350px|Visual indication of Fault in the system]]
  
 
Control Outputs are configured by defining one or more actions to be triggered on an output event.
 
Control Outputs are configured by defining one or more actions to be triggered on an output event.
Line 15: Line 15:
 
#Drag '''Fault Indication''' to the '''Control Output''' you want to use.
 
#Drag '''Fault Indication''' to the '''Control Output''' you want to use.
  
[[File:Fault indication 2.JPG|thumb|left|500px|Assigning Local Mute to a Control Output]]
+
[[File:Fault indication 2.JPG|thumb|left|500px|Assigning Fault Indication to a Control Output]]
 
<br style="clear:both;" />
 
<br style="clear:both;" />
  
Line 21: Line 21:
 
===Visual indication of a fault in the system===
 
===Visual indication of a fault in the system===
  
 +
 +
[[File:Fault indication 3.JPG|thumb|left|500px|Visual indication of errors in Zone 4]]
 +
<br style="clear:both;" />
  
 
==Parameter details==
 
==Parameter details==

Revision as of 07:40, 12 August 2016

Visual indication of Fault in the system

Control Outputs are configured by defining one or more actions to be triggered on an output event.

The Fault Indication functions is used to trig a control output when there is fault(s) in the system.

This can be used to send a signal to external systems (like BMG (Building Management Systems). It can also be used to give visual notifications when there is fault in the system.

Assigning Fault Indication to a Control Output

To assign the function Fault Indication to an Control Output:

  1. In Components view, open Output Actions
  2. In System, identify the Controller, the Amplifier or the Access Panel to be used, and expand to Device > Control Outputs.
  3. Drag Fault Indication to the Control Output you want to use.
Assigning Fault Indication to a Control Output


Configuration

Visual indication of a fault in the system

Visual indication of errors in Zone 4


Parameter details

Idle State: Sets the idle state for the output. The options are Normally Open or Normally Closed

Delay Activation: Delays control output activation for the stipulated number of seconds when triggered.

Reporting System: The system, i.e. System A, System B or System A and B, from which faults will be received (only available in A-B System projects).

Subscribe To: Options are Faults or Warnings.

Filter Parameters:

Affected Devices: Trigger on faults that affect selected devices.
Affected Zones: Trigger on faults that affect selected zones.
Affected Lines: Trigger on faults that affect selected audio lines.
Severity: Trigger on faults at selected levels.
Fault State: Trigger on faults in selected state.
System Message: Trigger on faults that have selected messages.

Advanced Options:

Limit High Not OK: When the Control Output is cleared, and feedback voltage is at or above this value, the output is considered fed with alien voltage.
Limit Low OK: When the Control Output is set, and feedback voltage is above this value, the output is considered active OK.