Difference between revisions of "Microphone Test"

From exigoWiki
Jump to navigation Jump to search
Line 2: Line 2:
  
 
Microphone Test is a variant of '''[[Recall]]''' where the audio is recorded with the microphone and "bounced" back to the access panel when the function times out or is switched off. The function can be used on [[ECPIR-3P]] or [[ECPIR-P]].
 
Microphone Test is a variant of '''[[Recall]]''' where the audio is recorded with the microphone and "bounced" back to the access panel when the function times out or is switched off. The function can be used on [[ECPIR-3P]] or [[ECPIR-P]].
 +
 +
== Configuration ==
  
 
* Drag-and-drop Input Actions -> Microphone Test to:
 
* Drag-and-drop Input Actions -> Microphone Test to:

Revision as of 07:24, 7 April 2017

Microphone test function
Microphone test

Microphone Test is a variant of Recall where the audio is recorded with the microphone and "bounced" back to the access panel when the function times out or is switched off. The function can be used on ECPIR-3P or ECPIR-P.

Configuration

  • Drag-and-drop Input Actions -> Microphone Test to:

Access Panel -> Control Inputs -> CI -> CI_1-CI_6 -> on_action/off_action

or

Access Panel -> Programmable Keys -> Key -> p1-px -> press_action/release_action

Settings

Microphone test function
Microphone test


Activation
Start, Stop or Toggle the broadcast.

Enable Timeout
Decides whether the function will timeout or not.

Timeout
The amount of time in seconds the broadcast will be active before it switches off.

Wait for PTT
Requires use of Press-To-Talk (M-key) when recording starts.

Led behavior

Green led active: Microphone is recording Red led active: Recorded audio is played back on local speaker

Use cases:

Case 1: Toggle

Parameters
Activation Toggle
Timeout 5
Wait for PTT Not set

Pressing this button will allow the operator to talk into the mic for up to 5 seconds or until the operator press the button again. The recorded message will then be played out.

Case 2: Start/Stop

Here microphone test should have activation set to start on press and stop on release. The button will then work as a PTT button, where the operator press and hold the button to record the message. When the operator release the button, or the function times out, the recording will be played back.

Case 3: Microphone test with handheld microphone

If a handheld microphone is used on the access panel the "wait for PTT" should be set.

Parameters
Activation Toggle
Timeout 5 seconds
Wait for PTT Set

Pressing the microphone test button will prime the panel. When the PTT button is pressed on the handheld microphone the microphone test will start and it will continue until it times out or the ptt button is released. If the PTT button on the handheld microphone is not pressed for 5 second the function will time out and the access panel will be back to normal functionality.

Availability

This function is available on Exigo 1.2 and newer.