Revision as of 11:00, 6 April 2017
This article describes the configuration needed when distributing General Alarm and high priority live speech from Exigo to AlphaCom/ACM.
- It is important that users of AlphaCom/ACM are not able to disconnect the Exigo PA call from the InterCom station.
- All audio from Exigo to AlphaCom/ACM will be distributed with handset and volume override.
Configuration Example
Group number, program number, directory number and cos can of cause be changed to user request.
EMT
Exigo | Description |
AlphaCom Feature added as member of Zone "AlphaCom/ACM" | 8075 |
Configuration in Exigo Management Toll (EMT):
- Drag AlphaCom Feature to System -> Integration -> AlphaCom
- Drag the configured AlphaCom Feature to the designated zone
AlphaPro
Overview of configuration in AlphaPro:
AlphaCom | Description | Info |
Station group used in AlphaCom to include stations receiving EXIGO calls | Group 10 | NB! The group feature/directory number is not used. Only the list of group members |
Program Channel used for audio distribution | Program 7, Flags set: Program over Conversation, Volume/Handset Override | NB! The program feature/directory number is not used. NB! The program channel must not be related to physical hardware. (AGA/APC) |
Feature for triggering audio to ACM stations inn group 10 | "8075" "Exigo Call" Feature 118, Param1 = 7 , Param2 = 10 |
Will start Program 7 to all members of group 10 |
Event handler for inhibit program selection during Exigo call. This will deactivate dialing "800" for canceling program during PAGA. |
15-Event Trigger Feature Sub event: 10 When Change To: ON When related to directory number : 8075 Action: $MCC U1 U5 U0 $MCC U2 U5 U0 $MCC U3 U5 U0 $MCC U4 U5 U0 $MCC U5 U5 U0 $MCC U16 U5 U0 |
Removes 5- Audio Program Selection from Class Of Service 1,2,3,4,5 and 16 Should be adjusted to reflect the COS actually used in the system. |
Event handler trigger for enabling program selection again after Exigo call | 15-Event Trigger Feature Sub event: 10 When Change To: OFF When related to directory number : 8075 Action: $MCC U1 U5 U1 $MCC U2 U5 U1 $MCC U3 U5 U1 $MCC U4 U5 U1 $MCC U5 U5 U1 $MCC U16 U5 U1 |
Add 5- Audio Program Selection to Class Of Service 1,2,3,4,5 and 16 Should be adjusted to reflect the COS actually used in the system. |
Add feature 118 "Program Source" to Class of service 15 (Outside telephone) |
- Configuration of Group
- Configuration of Audio Program
Availability
This function is available from Exigo 1.3 and newer.