Difference between revisions of "System Downgrade"

From exigoWiki
Jump to navigation Jump to search
Line 7: Line 7:
 
# Download and install the VS-AlphaCComXEImageUpgrade
 
# Download and install the VS-AlphaCComXEImageUpgrade
 
# Download the latest 1.2 software package
 
# Download the latest 1.2 software package
 
+
 
===AMC-IP===
 
===AMC-IP===
 
* Open the VS-AlphaCComXEImageUpgrade and select "Select Image File".  
 
* Open the VS-AlphaCComXEImageUpgrade and select "Select Image File".  
Line 13: Line 13:
 
* Select "axeu_b3001_a1101303.aimg"
 
* Select "axeu_b3001_a1101303.aimg"
 
* If server status says: "Could not start HTTP server", a TFTP-server is needed to transfer the image to the AMC-IP.  
 
* If server status says: "Could not start HTTP server", a TFTP-server is needed to transfer the image to the AMC-IP.  
 
+
 
[[File:Alphacomimageupgrade.PNG|thumb|left|500px|Alphacom ImageUpgrade window]]
 
[[File:Alphacomimageupgrade.PNG|thumb|left|500px|Alphacom ImageUpgrade window]]
 
<br style="clear:both;" />
 
<br style="clear:both;" />
 
+
 
* Load a tftp-server and set the root folder to:"... \Vingtor Stentofon\VS-Tools\HttpFileServerRoot".  
 
* Load a tftp-server and set the root folder to:"... \Vingtor Stentofon\VS-Tools\HttpFileServerRoot".  
 
* Write the IP of the AMC-IP that will be flashed --> Connect to target
 
* Write the IP of the AMC-IP that will be flashed --> Connect to target
 
* If the status window shows: "Bootloader Status Recived - Status OK", everything is ready --> Press "Start Image Upgrade"
 
* If the status window shows: "Bootloader Status Recived - Status OK", everything is ready --> Press "Start Image Upgrade"
 
+
 
When the progress bar is at 100%, navigate to AlphaWeb and verify that versions are:
 
When the progress bar is at 100%, navigate to AlphaWeb and verify that versions are:
 
* Alphasys: 11.1.3.3
 
* Alphasys: 11.1.3.3
 
* BSP: 31.01
 
* BSP: 31.01
 
+
 
[[File:Amcip_after_flash.PNG|thumb|left|500px|Alphasys and BSP after flash]]
 
[[File:Amcip_after_flash.PNG|thumb|left|500px|Alphasys and BSP after flash]]
 
<br style="clear:both;" />
 
<br style="clear:both;" />

Revision as of 11:17, 14 March 2017

This article describes how to downgrade an Exigo system between major releases.


Downgrade 1.3 to 1.2

Prerequisites

  1. Download and install the VS-AlphaCComXEImageUpgrade
  2. Download the latest 1.2 software package

AMC-IP

  • Open the VS-AlphaCComXEImageUpgrade and select "Select Image File".
  • Navigate to "... Vingtor Stentofon\VS-Tools\AlphaComImages"
  • Select "axeu_b3001_a1101303.aimg"
  • If server status says: "Could not start HTTP server", a TFTP-server is needed to transfer the image to the AMC-IP.
Alphacom ImageUpgrade window


  • Load a tftp-server and set the root folder to:"... \Vingtor Stentofon\VS-Tools\HttpFileServerRoot".
  • Write the IP of the AMC-IP that will be flashed --> Connect to target
  • If the status window shows: "Bootloader Status Recived - Status OK", everything is ready --> Press "Start Image Upgrade"

When the progress bar is at 100%, navigate to AlphaWeb and verify that versions are:

  • Alphasys: 11.1.3.3
  • BSP: 31.01
Alphasys and BSP after flash