This article explains how to start alarm from AlphaCom on a Exigo A-B system.
Guide on how to set up the redundant AlphaCom integration can be found here.
Starting an alarm from AlphaCom to a redundant Exigo system is done by starting a group call in AlphaCom that starts the Alarm Generator in both Exigo A and B controller.
AlphaPro Configuration
- Set up the redundant AlphaCom integration following this guide.
- Set up 2 different DirNo numbers (for example 98001 and 98002) as SIP stations related to PSC A and PSC B trunk:
98001 Setup:
Notice the related to trunk.
98002 Setup:
Notice the related to trunk.
- Make a group and add both dir numbers (98001 and 98002) to the group to be able to call both at the same time from a station:
- Add both dir numbers (98001 and 98002) to the group:
- Now program a DAK to call that group – in this case dir 85 – and this will start the alarm in both Exigo A and B.
EMT Configuration
- Configure two identical Action Calls with the same directory numbers used in AlphaPro (for example 98001 and 98002).
These two Action Calls will now be started by the group call from AlphaCom.