+ | # Log on to the Station web interface. Default login credentials are '''admin''' and '''alphaadmin'''. Select Station Administration > Manual Upgrade | ||
+ | # Enter the IP address of the TFTP server (I.e. the IP address of your PC) | ||
+ | |||
+ | # Enter the image file: exi-x.x.x.x, and click Save settings | ||
[[Category:How-To]] | [[Category:How-To]] |
Revision as of 11:06, 24 June 2016
The Exigo System Controller consist of two main components:
- Primary System Controller, PSC
- Secondary System Controller, SSC
This article describes how to upgrade the software on the Secondary System Controller part of the Exigo System Controller.
Upgrade using the Web Interface
Prerequisites
- A TFTP Server must be available. A TFTP server can be downloaded from here: http://tftpd32.jounin.net/tftpd32_download.html
- Download the latest Exigo firmware/software package and unzip the folder.
- Check if your local firewall is not blocking incoming ping/ICMP (Turbine station is pinging TFTP Server during update process).
Upgrade procedure
- Start the TFTP server program and click Browse, and select the folder where the latest version of exi-x.x.x.x software files are located
- Log on to the Station web interface. Default login credentials are admin and alphaadmin. Select Station Administration > Manual Upgrade
- Enter the IP address of the TFTP server (I.e. the IP address of your PC)
- Enter the image file: exi-x.x.x.x, and click Save settings