Difference between revisions of "Backup Request"

From exigoWiki
Jump to navigation Jump to search
(Configuration)
 
(21 intermediate revisions by 3 users not shown)
Line 1: Line 1:
 +
[[File:Backup amplifier 1.JPG|thumb|right|500px|Backup Amplifier]]
 +
This article describe the Backup Request feature.
 +
This optional function may be used together with the '''[[Backup Amplifier|Backup Amplifier]]''' function.
  
This article describe the Backup Request feature. This optional function may be used together with the '''Backup Amplifier''' function.  
+
Backup Request is used to configure a control input on a backup amplifier to be able to replace the functions of the chosen failed amplifier. <br>
 +
The backup request is a feature to ensure an even faster switch-over if the defective amplifier has a power issue.
  
The '''Backup Request''' is a feature to ensure an even faster switch-over if the defect amplifier has a power issue.
 
  
 
+
== Configuration ==
== Assigning Backup Request to an Control Input ==
+
* Drag-and-drop '''Backup Request''' to:
To assign the Backup Request to an control input on a backup amplifier:
+
'''Backup Amplifier''' > '''Control Inputs''' > '''CI_1-CI_6''' > '''on_action/off_action'''
#In '''Components''' view, open '''Input Actions'''.
+
[[File:Backup request 3.JPG|thumb|left|500px|Assigning Backup Request to a Control Input]]
#In '''System''', identify the backup amplifier be used, and expand to '''Amplifier > Control Inputs > CI_X'''.
 
#Drag '''Backup Request''' to the '''Control Input'''.
 
 
 
[[File:Backup request 2.JPG|thumb|left|500px|Assigning an Audio Program Source to the input of the ESC Controller]]
 
 
<br style="clear:both;" />
 
<br style="clear:both;" />
  
 +
In this example, the backup amplifier will receive a '''Backup Request''' from '''ENA2200 1'''.
  
== Configuration ==
+
== Parameter Details ==
 
 
  
 +
[[File:Backup request 4.png|thumb|left|450px|Backup Request - parameter details]]
 +
<br style="clear:both;" />
  
== Parameter details ==
+
'''<u>Amplifier</u>''' <br>
 
+
Select the amplifier to back up.
  
 +
== Configuration on Amplifier that is being Backed Up ==
 +
You also need to configure a control output on the amplifier that is being backed up:
  
 +
[[File:Backup_amplifier_configuration_4.JPG|thumb|left|600px|Control Output Configuration]]
 +
<br style="clear:both;" />
 +
* In '''System''' select the desired amplifier.
 +
* Select the '''Control Output''' you want to use
 +
* Set the '''Control Output''' to '''Normally Closed'''
  
 +
Wire the '''Control Output''' on the amplifier to the '''Control Input''' on the backup amplifier.<br>
 +
If the amplifier loses power, the '''Control Output''' will open and the '''Backup Request''' functionality will trigger. 
  
 +
== Availability ==
 +
This function is available from Exigo 1.3 and later.
  
 
[[Category:Exigo features]]
 
[[Category:Exigo features]]
 
[[Category:Input Actions]]
 
[[Category:Input Actions]]

Latest revision as of 15:31, 3 May 2018

Backup Amplifier

This article describe the Backup Request feature. This optional function may be used together with the Backup Amplifier function.

Backup Request is used to configure a control input on a backup amplifier to be able to replace the functions of the chosen failed amplifier.
The backup request is a feature to ensure an even faster switch-over if the defective amplifier has a power issue.


Configuration

  • Drag-and-drop Backup Request to:

Backup Amplifier > Control Inputs > CI_1-CI_6 > on_action/off_action

Assigning Backup Request to a Control Input


In this example, the backup amplifier will receive a Backup Request from ENA2200 1.

Parameter Details

Backup Request - parameter details


Amplifier
Select the amplifier to back up.

Configuration on Amplifier that is being Backed Up

You also need to configure a control output on the amplifier that is being backed up:

Control Output Configuration


  • In System select the desired amplifier.
  • Select the Control Output you want to use
  • Set the Control Output to Normally Closed

Wire the Control Output on the amplifier to the Control Input on the backup amplifier.
If the amplifier loses power, the Control Output will open and the Backup Request functionality will trigger.

Availability

This function is available from Exigo 1.3 and later.