Difference between revisions of "Activity Indicator"

From exigoWiki
Jump to navigation Jump to search
Line 2: Line 2:
 
[[File:Activity_indicator.png|thumb|alt=Activity Indicator function|Activity Indicator]]
 
[[File:Activity_indicator.png|thumb|alt=Activity Indicator function|Activity Indicator]]
  
The "Activity Indicator" function is a function which can be assigned to any dak button on any [[access panels]]. This will designate the complete button as an activity indicator which indicates activity in the selected [[zone]]s with activite in the [[priority]] range.
+
The "Activity Indicator" function is a function which can be assigned to any dak button on any [[access panels|access panel]]. This will designate the complete button as an activity indicator which indicates activity in the selected [[zone]]s with activity in the [[priority]] range.
  
 
This function can not be used on Control Inputs.
 
This function can not be used on Control Inputs.
 +
 
==Settings==
 
==Settings==
 
[[File:Activity_indicator.png|alt=Activity Indicator function|Activity Indicator]]
 
[[File:Activity_indicator.png|alt=Activity Indicator function|Activity Indicator]]

Revision as of 14:32, 3 June 2016

Activity Indicator function
Activity Indicator

The "Activity Indicator" function is a function which can be assigned to any dak button on any access panel. This will designate the complete button as an activity indicator which indicates activity in the selected zones with activity in the priority range.

This function can not be used on Control Inputs.

Settings

Activity Indicator function

Parameters
Destination Select which zones should be monitored for activity
Priority Ignore activity which falls outside of this priority range

Use cases:

Case 1: Indicate alarm status

In this case the button was used to indicate that a specific alarm was used. To solve this the alarm got a unique priority and the "Activity indicator" was set to filter out all other activity. The alarm got priority 21.

Parameters
Destination None
Priority 20-21

With the selected parameters the function will only check priority. As the alarm was the only alarm with priority 21 setting the priority field to a narrow selection of alarms between 20 and 21 no other activity will fullfill the requirements.

Case 2: Indicate activity in one zone

In this case the button was used to indicate that there was activity in zone 4 or zone 5.

Parameters
Destination Zone 4 and zone 5
Priority 1-100

The settings will in effect ignore the priority field and only filter on zones. If there is any activity in either zone 4 or zone 5 the activity led will be triggered.

Availability

This function is available on Exigo 1.2 and newer.