Setting up a small A-B system

From exigoWiki
Revision as of 11:40, 22 August 2016 by Gsorensen (talk | contribs) (Step 1: IP address)
Jump to navigation Jump to search
Exigo small A-B system

This article will explain how to setup and configure a small Exigo A-B system.
System A will have one ESC1 Controller and two ENA2200 Amplifiers.
System B will have one ESC1 Controller and two ENA2200 Amplifiers.
In addition there will be one ECPR-3P connected to the system.
The system will be programmed with 4 Zones.
With the PPT button we will configure Live Speech on all zones.

Before you start configure make sure that all devices have been updated to the latest software/firmware.

Step 1: IP address

Each device will need to be configured with an IP address and subnet which is in range of the AMC-IP card.

Table below lists IP range for a small system with one amplifier and on access panel. All subnets are set to 255.255.255.0

Device IP Directory number
PSC System A 10.5.11.11
ESC-1 System A 10.5.11.100 013010
ENA 1 System A 10.5.11.110 012010
ENA 2 System A 10.5.11.120 012020
PSC System B 10.5.12.11
ESC-1 System B 10.5.12.100 023010
ENA 1 System B 10.5.12.110 022010
ENA 2 System B 10.5.12.120 022020
ECPIR-3P 10.5.11.200 011010