Activity Indicator

From exigoWiki
Revision as of 14:33, 10 February 2016 by Estromme (talk | contribs)
Jump to navigation Jump to search
Activity Indicator function
Activity Indicator

The "Activity Indicator" function is a function which can be assigned to any dak button on any access panels. This will designate the complete button as an activity indicator which indicates activity in the selected zone(s) with inside the priority range.

Settings

Activity Indicator function

Destination Select which zones should be monitored for activity
Priority Ignore activity which falls outside of this priority range

Example of use

Case 1: Indicate alarm status

In this case the button was used to indicate that a specific alarm was used. To solve this the alarm got a unique priority and the "Activity indicator" was set to filter out all other activity. The alarm got priority 21.

Field Parameters
Destination None
Priority 20-21

With the selected parameters the function will only check priority. As the alarm was the only alarm with priority 21 setting the priority field to a narrow selection of alarms between 20 and 21 no other activity will fullfill the requirements.

Case 2: Indicate activity in one zone

In this case the button was used to indicate that there was activity in zone 4 or zone 5.

Field Parameters
Destination Zone 4 and zone 5
Priority 1-100

The settings will in effect ignore the priority field and only filter on zones. If there is any activity in either zone 4 or zone 5 the activity led will be triggered.