OID Logical name Frequency Unit Priority Description
Memory usage MIB2 Memory usage Once every 60 second All
1.3.6.1.4.1.26122.3.1.4 infoAmplifierType During startup All The device Amplifier Type
1.3.6.1.4.1.26122.3.1.1 infoPackageVersion During startup All The device Package Version
1.3.6.1.4.1.26122.3.2 temp
1.3.6.1.4.1.26122.3.2.1 tempTableCount Number of Temperature entries in tempTable
1.3.6.1.4.1.26122.3.2.2.1.2 tempSensorName During startup SSC + ENA
1.3.6.1.4.1.26122.3.2.2.1.7 tempAverageString During startup SSC + ENA
1.3.6.1.4.1.26122.3.2.2.1.8 tempAverageValue Twice every 60 second SSC + ENA
1.3.6.1.4.1.26122.3.3 fan
1.3.6.1.4.1.26122.3.3.1 fanTableCount During startup SSC + ENA
1.3.6.1.4.1.26122.3.3.2.1.2 fanString During startup SSC + ENA
1.3.6.1.4.1.26122.3.3.2.1.3 fanValue Once every 60 second SSC + ENA
1.3.6.1.4.1.26122.3.7 ampChannel
1.3.6.1.4.1.26122.3.7.1 ampChannelCount During startup ENA
1.3.6.1.4.1.26122.3.7.3.1.2 ampChannelString During startup ENA
1.3.6.1.4.1.26122.3.7.3.1.3 ampChannelStatus: unknown(1), notOperative(2), channelOk(3), channelFail(4), channelShutdown(5), channelGracefulDegradation(6) Once every 60 second ENA High
1.3.6.1.4.1.26122.3.6 lineIn Panels
1.3.6.1.4.1.26122.3.6.1.1.5 lineInStatus: unknown(1), lineInOk(2), lineInFail(3), microphoneUnknown(4), microphoneConnected(5), microphoneDisconnected(6), microphoneShorted(7) Once every 60 second Panels