Flowire Monitoring

From exigoWiki
Revision as of 12:18, 13 September 2016 by Gsorensen (talk | contribs)
Jump to navigation Jump to search

This article describe how to enable monitoring for the Flowires that are connected to the system.
It is possible to monitor the Flowires that are connected to the system.
This will give a better error reporting and easier troubleshooting if an error should occur.

EMT Configuration

Monitoring of the Flowires must be configured using EMT.

  • Go to Configuration view
  • In the device tree go to System -> Flowires
EMT - Flowires


Select the Add button (beside the trashcan) to add a new Flowire to the system.

EMT - Flowires


Feature: This is automatically generated by EMT. The first Flowire will have flow001, the next flow002 and so on.

Display Name: It is recomended to give the Flowires a descriptive name. The name will be displayed in the fault list if a Flowire looses connection.
A good descriptive name will make it easier to troubleshoot if an fault occurs.

Flowire Configuration

Configuration of the Flowire is done thru the Web interface of the Flowire.
If there is no DHCP server on the network, the Flowire units will by default have a static IP address 169.254.1.10.

  • Go to the Web interface of the Flowire
Flowire Web Interface


Next press the Upgrade form button.

Flowire Web Interface


Next press the Exigo form button.

Flowire Web Interface


This is where the configuration of the Flowire is done.
DOMAIN_ADDRESS: This is the IP address for the Primary System Controller (PSC).

DOMAIN_PORT: This is the ZAP port being

USERNAME: The first Flowire will have flow001, the next flow002 and so on