Activity Indicator

From exigoWiki
Revision as of 12:50, 2 May 2018 by Gsorensen (talk | contribs) (Configuration)
Jump to navigation Jump to search
Activity Indicator function
Activity Indicator

The Activity Indicator function can be assigned to any DAK button on any access panel. This will designate the button as an indicator for activity in the selected zones within the priority range.

This function cannot be used on Control Inputs.

Configuration

  • Drag-and-drop Activity Indicator to:

Access Panel -> Programmable Keys -> p1-px -> press_action/release_action

Activity Indicator - Parameters


Destination
Select which zones to monitor for activity.

Priority Range
Ignore activity that falls outside this priority range.

Use Cases

Case 1: Indicate Alarm Status

In this case, the button is used to indicate that a specific alarm is activated. To obtain this, we give the alarm a unique priority (21), and the Activity Indicator is set to filter out all other activities.

Parameters
Destination None
Priority Range 20-21

With the selected parameters, the function will only check priority. If the alarm is the only one with priority 21, setting the priority field to a narrow range of alarms between 20 and 21 means that no other activity will fulfill the required parameters, thus not triggering the Activity Indicator.

Case 2: Indicate Activity in One Zone

In this case, the button is used to indicate that there is activity in Zone 4 or Zone 5.

Parameters
Destination Zone 4 and Zone 5
Priority 1-100

The settings will in effect ignore the priority field and only filter on zones. If there is any activity in either Zone 4 or Zone 5, the activity LED will then be triggered.

Availability

This function is available from Exigo version 1.2.