Follow Any Alarm Tone
Control Outputs are configured by defining one or more actions to be triggered on an output event.
The Follow Any Alarm Tone function is used to trigger the control output to follow any alarm tone in one specific zone.
Contents
Assigning Follow Any Alarm Tone to a Control Output
To assign the function Follow Any Alarm Tone to an Control Output:
- In Components view, open Output Actions
- In System, identify the Controller, the Amplifier or the Access Panel to be used, and expand to Device > Control Outputs.
- Drag Follow Any Alarm Tone to the Control Output you want to use.
Configuration
Follow alarm tone in Zone 1
- Drag Follow Any Alarm Tone to the desired Control Output.
- Select the desired Alarm (or Any) in Source.
- Select Zone 1 in Zone.
In this example the General Alarm (Ship) in Zone 1 will trig Control Output 1.
Parameter details
Idle State: Sets the idle state for the output. The options are Normally Open or Normally Closed
Delay Activation: Delays control output activation for the stipulated number of seconds when triggered.
Source: The source that will trigger the alarm output. If Source is not specified, it will be ignored when checking whether the conditions for the audio activity triggering are present or not.
Zone: The zones in which the output on an activity is triggered. If Zone is not specified, it will be ignored when checking whether the conditions for the audio activity triggering are present or not. Note that only one zone can be specified.
Priority Range: The priority range within which the activity is triggered.
Advanced Options:
- Limit High Not OK: When the Control Output is cleared, and feedback voltage is at or above this value, the output is considered fed with alien voltage.
- Limit Low OK: When the Control Output is set, and feedback voltage is above this value, the output is considered active OK.