Activity Indicator
The "Activity Indicator" function can be assigned to any dak button on any access panel. This will designate the button as an indicator for activity in the selected zones within the priority range.
This function can not be used on Control Inputs.
Contents
Settings
Parameters | |||||
---|---|---|---|---|---|
Destination | Select which zones should be monitored for activity | ||||
Priority | Ignore activity which falls outside of this priority range |
Use cases:
Case 1: Indicate alarm status
In this case the button was used to indicate that a specific alarm was used. To solve this the alarm got a unique priority and the "Activity indicator" was set to filter out all other activity. The alarm got priority 21.
Parameters | |||||
---|---|---|---|---|---|
Destination | None | ||||
Priority | 20-21 |
With the selected parameters the function will only check priority. As the alarm was the only alarm with priority 21 setting the priority field to a narrow selection of alarms between 20 and 21 no other activity will fullfill the requirements.
Case 2: Indicate activity in one zone
In this case the button was used to indicate that there was activity in zone 4 or zone 5.
Parameters | |||||
---|---|---|---|---|---|
Destination | Zone 4 and zone 5 | ||||
Priority | 1-100 |
The settings will in effect ignore the priority field and only filter on zones. If there is any activity in either zone 4 or zone 5 the activity led will be triggered.
Availability
This function is available on Exigo 1.2 and newer.