SNMP recommended parameters

From exigoWiki
Revision as of 08:21, 13 June 2019 by Gsorensen (talk | contribs) (Exigo 1.2.3.13)
Jump to navigation Jump to search

This article describes the SNMP parameters that are recommended to monitor.


Exigo 1.2.3.13

Exigo 1.2.3.13 is using SNMPv1.

OID Logical name Frequency Unit Priority
Memory usage MIB2 Memory usage Once every 60 second All
1.3.6.1.4.1.26122.3.1.4 infoAmplifierType During startup All
1.3.6.1.4.1.26122.3.1.1 infoPackageVersion During startup All
1.3.6.1.4.1.26122.3.2 temp
1.3.6.1.4.1.26122.3.2.1 tempTableCount
1.3.6.1.4.1.26122.3.2.2.1.2 tempSensorName During startup SSC + ENA
1.3.6.1.4.1.26122.3.2.2.1.7 tempAverageString During startup SSC + ENA
1.3.6.1.4.1.26122.3.2.2.1.8 tempAverageValue Twice every 60 second SSC + ENA
1.3.6.1.4.1.26122.3.3 fan
1.3.6.1.4.1.26122.3.3.1 fanTableCount During startup SSC + ENA
1.3.6.1.4.1.26122.3.3.2.1.2 fanString During startup SSC + ENA
1.3.6.1.4.1.26122.3.3.2.1.3 fanValue Once every 60 second SSC + ENA
1.3.6.1.4.1.26122.3.7 ampChannel
1.3.6.1.4.1.26122.3.7.1 ampChannelCount During startup ENA
1.3.6.1.4.1.26122.3.7.3.1.2 ampChannelString During startup ENA
1.3.6.1.4.1.26122.3.7.3.1.3 ampChannelStatus Once every 60 second ENA
unknown(1)
notOperative(2)
channelOk(3)
channelFail(4)
channelShutdown(5)
channelGracefulDegradation(6)