Difference between revisions of "Redundant AlphaCom integration"

From exigoWiki
Jump to navigation Jump to search
(EMT Configuration)
(Step 2. Action Calls)
Line 110: Line 110:
 
=== Step 2. Action Calls ===
 
=== Step 2. Action Calls ===
 
For the AlphaCom to trigger features in the Exigo system one or more '''Action Calls''' needs to be added.<br>
 
For the AlphaCom to trigger features in the Exigo system one or more '''Action Calls''' needs to be added.<br>
For redundancy we need identical '''Action Call''' to be started in both controllers.
+
For redundancy we need identical '''Action Call''' to be started in both controllers.<br>
 
In Components view expand '''External Connections'''.<br>
 
In Components view expand '''External Connections'''.<br>
 
Drag '''Action Call''' to '''System''' -> '''Integration''' -> '''Action Calls''':
 
Drag '''Action Call''' to '''System''' -> '''Integration''' -> '''Action Calls''':
 
[[File:Alphacom integration 11.JPG|thumb|left|500px|EMT - Add Action Call]]
 
[[File:Alphacom integration 11.JPG|thumb|left|500px|EMT - Add Action Call]]
 
<br style="clear:both;" />
 
<br style="clear:both;" />
 +
Repeat the process so that you have minimum two '''Action Calls'''.
  
 
Then you can add input action to the '''Action Call'''. We will use '''Live Speech''' in this example.<br>
 
Then you can add input action to the '''Action Call'''. We will use '''Live Speech''' in this example.<br>
 
In Components view expand '''Input action'''.<br>
 
In Components view expand '''Input action'''.<br>
Drag '''Live Speech''' to '''System''' -> '''Integration''' -> '''Action Calls''' -> '''980xx''' -> '''On Connect'''
+
Drag '''Live Speech''' to '''System''' -> '''Integration''' -> '''Action Calls''' -> '''98001''' -> '''On Connect'''
 
[[File:Alphacom integration 12.JPG|thumb|left|500px|EMT - Add Live Speech]]
 
[[File:Alphacom integration 12.JPG|thumb|left|500px|EMT - Add Live Speech]]
 
<br style="clear:both;" />
 
<br style="clear:both;" />

Revision as of 13:33, 2 February 2017

This article explains how to setup and configure redundant AlphaCom integration on an Exigo A-B system.
The solution may also be used for Exigo system with hot-standby controller.
Redundant AlphaCom integration makes it possible for the AlphaCom to call both Exigo Controllers simultaneously.
If one of the Exigo Controllers fails you will still have integration between AlphaCom and the Exigo system.


Configuration Overview

Exigo Management Tool (EMT) is used for setting up the integration from Exigo.

EMT


AlphaPro is used for setting up the integration from AlphaCom.

AlphaPro


From Exigo there is two types of actions defined:

  • Action Calls - from AlphaCom to Exigo.
  • AlphaCom features - from Exigo to AlphaCom.

Exigo will use numbers from 98001 to 98099 to start activities in Exigo on incoming activities.
Outgoing from Exigo can define any number.

AlphaPro Configuration

Configuration on the AlphaCom with redundant call to Exigo contains three steps:

  • Define and map IP addresses to the two Exigo Nodes (Controller A and Controller B).
  • Defining Directory Numbers.
  • Make a Group Call that calls both controllers.


Step 1. Define and map IP addresses to the first Exigo Node (Controller A)

The following steps needs to be repeated for Controller B.
Select Create Exchange to create the first Exigo SIP node in your AlphaCom system:

AlphaPro - Create exchange


Set the IP adress for the first Exigo PSC (Controller A) as the SIP Trunk Line:

AlphaPro - Set the Exigo PSC IP address as the SIP Trunk Line


Set up Net Routing:
Go to Exchange & System -> Net Routing:

AlphaPro - Setup the Net Routing


Select Insert:
Select the Exigo node:

AlphaPro - Setup the Net Routing


Select ACDP Link: SIP Link (31)

File:Alphacom integration net routing 3.JPG
AlphaPro - Setup the Net Routing


Press OK. The steps above must then be repeated for Controller B.

After adding both controllers you should now have two Exigo nodes:

Net Routing - both controllers


Step 2. Defining Directory Numbers

In order to achieve redundancy the AlphaCom needs to call both controllers at the same time.
The next step is to add the directory numbers which are used in Exigo. These numbers are from 98001 to 98099: Select Directory and Features:

AlphaPro - Directory and Features


Here you need to add the number of directory numbers/Action Calls you need.
For redundancy you need to add minimum two numbers (for example 98001 and 98002).
98001 will then call Controller A, and 98002 will call Controller B.
Add a directory number 98001 with feature number 9 (Call a User).

AlphaPro - Directory and Features


This will give you a number that are automatically in All Call 84, and can also be added to groups.
Give the Directory Number a descriptive text in Display Text.
The User will look like this:

AlphaPro - User


Check the SIP Station box.
The Related to Trunk must be set to the correct Exigo SIP Trunk (one for each Exigo Controller).
For redundancy you need two numbers.
For example will 98001 call Controller A (node 2), and 98002 Controller B (node 3):

98001 - Node 3 (Controller 2)


Step 3. Group Call

In order to achieve redundancy AlphaCom needs to call both Exigo Controllers at the same time.
This is done by doing a Group Call from AlphaCom.
Go to Groups -> Local Groups. Edit (change) an available group and include the two member (for example 98001 and 98002):

Group Call - Calling both Controllers


This Group Call will then make sure that AlphaCom call both Exigo Controllers simultaneously.

EMT Configuration

There is 3 main configurations that needs to be done in EMT:

  • The AlphaCom node needs to be added.
  • Actions Calls and
  • AlphaCom features also needs to be configured.

Step 1. Add the AlphaCom node

First step is to add the AlphaCom node to the system.
In Components view expand the External Devices.
Drag the AlphaCom to the System -> Integration:

EMT - Add the AlphaCom node


Type in the IP address of the AlphaCom.

Step 2. Action Calls

For the AlphaCom to trigger features in the Exigo system one or more Action Calls needs to be added.
For redundancy we need identical Action Call to be started in both controllers.
In Components view expand External Connections.
Drag Action Call to System -> Integration -> Action Calls:

EMT - Add Action Call


Repeat the process so that you have minimum two Action Calls.

Then you can add input action to the Action Call. We will use Live Speech in this example.
In Components view expand Input action.
Drag Live Speech to System -> Integration -> Action Calls -> 98001 -> On Connect

EMT - Add Live Speech


In the pop up select:

  • Activation: Start.
  • Destination: The zones you want the Live Speech.
  • Priority: Default priority is 50.
  • Chime: Select the desired chime.

Press Done.
To make the Live Speech stop you also need to program Live Speech on disconnect.
This needs to have Activation: Stop.

Availability

This feature is available from Exigo 1.3.2.7 and newer.