Difference between revisions of "Flowire Software Upgrade Procedure"

From exigoWiki
Jump to navigation Jump to search
(Upgrade using VS-IMT)
Line 49: Line 49:
  
 
=== Upgrade using VS-IMT ===
 
=== Upgrade using VS-IMT ===
Content will come..
+
A guide to upgrade using VS-IMT can be found in the [https://www.zenitel.com/product/fcdc2 A100K11422 Flowire Configuration Manual].
  
 
[[Category:Software upgrade]]
 
[[Category:Software upgrade]]

Revision as of 10:09, 13 September 2016

Flowire

This article describes how to upgrade the software in Flowire devices.

There are different ways, depending on how old the current software is:

  • If the current software is 4.x, the upgrade can be done from the web page of the Flowire unit, or by using the VS-IMT tool
  • If the current software is 1.x or 2.x, please contact alphasupport for further advice.

How to determine the current software version

  • Hardware version 0105 (Item: 1008080110.0105) and newer has version 4.x installed from factory, and can be upgraded via the web interface or via the VS-IMT tool.
  • Hardware version 0104 (Item: 1008080110.0104) and older has version 1.x or 2.x installed from factory, and must be updated via the serial interface.


You can also check the Flowire unit from you PC: If you can ping the device, but not access it via the web browser, it is an old software version and it must be upgraded via the serial interface.

Upgrading from software version 4.x

Upgrade via the Flowire Web Interface

Flowire units with software version 4.x can be upgraded through the web interface of the Flowire.

The Flowire units are automatically assigned an IP address from the network if there is a DHCP server present. You can then access the Flowire units web interface one by one and perform the upgrade.

If there is no DHCP server on the network, the Flowire units will by default have a static IP address 169.254.1.10. In this case there will be multiple Flowire units with the same IP address on the network, and you need to isolate the Flowire unit which is going to be upgraded from the others in the network.

Isolating the Flowire units one by one


Although it is not necessary for the Flowire to perform its function, it is good practice to change the static IP to something unique at the same time, for easier maintenance in the future.

Prerequisites

  • TFTP Server: This upgrade method require that an TFTP Server is available. A TFTP Server program can be downloaded from http://tftpd32.jounin.net.
  • Software package: The latest software package must be downloaded from the download site. Unzip the files to a folder.


Upgrading

  • Start the TFTP server and Browse to the folder where the software files are stored.
TFTP server setup


Use a standard web browser and enter the IP address of the Flowire (e.g. 169.254.1.10) in the address field.

Flowire upgrade - enter TFTP server address


Enter the TFTP server IP address and select Upgrade.

Upgrade: Upgrades the software and keeps all custom settings
Full Upgrade: Upgrades the software and performs a reset to factory settings

As a precaution you should set the NMK again after update

Upgrade using VS-IMT

A guide to upgrade using VS-IMT can be found in the A100K11422 Flowire Configuration Manual.