Difference between revisions of "Setting up a small A-B system"

From exigoWiki
Jump to navigation Jump to search
(Step 1: IP address)
(Step 1: IP address)
Line 33: Line 33:
 
|-
 
|-
 
|ENA 2 System A
 
|ENA 2 System A
 +
|10.1.0.30
 +
|012010
 +
|-
 +
|PSC System B
 +
|10.1.0.21
 +
|
 +
|-
 +
|ESC-1 System B
 +
|10.1.0.20
 +
|013010
 +
|-
 +
|ENA 1 System B
 +
|10.1.0.30
 +
|012010
 +
|-
 +
|ENA 2 System B
 
|10.1.0.30
 
|10.1.0.30
 
|012010
 
|012010

Revision as of 11:33, 22 August 2016

Exigo small A-B system

This article will explain how to setup and configure a small Exigo A-B system.
System A will have one ESC1 Controller and two ENA2200 Amplifiers.
System B will have one ESC1 Controller and two ENA2200 Amplifiers.
In addition there will be one ECPR-3P connected to the system.
The system will be programmed with 4 Zones.
With the PPT button we will configure Live Speech on all zones.

Before you start configure make sure that all devices have been updated to the latest software/firmware.

Step 1: IP address

Each device will need to be configured with an IP address and subnet which is in range of the AMC-IP card.

Table below lists IP range for a small system with one amplifier and on access panel. All subnets are set to 255.255.255.0

Device IP Directory number
PSC System A 10.1.0.21
ESC-1 System A 10.1.0.20 013010
ENA 1 System A 10.1.0.30 012010
ENA 2 System A 10.1.0.30 012010
PSC System B 10.1.0.21
ESC-1 System B 10.1.0.20 013010
ENA 1 System B 10.1.0.30 012010
ENA 2 System B 10.1.0.30 012010
ECPIR-3P 10.1.0.50 011010