Difference between revisions of "Activity Indicator"
Rlorentzen (talk | contribs) (→Availability) |
|||
Line 1: | Line 1: | ||
− | + | ||
[[File:Activity_indicator.png|thumb|alt=Activity Indicator function|Activity Indicator]] | [[File:Activity_indicator.png|thumb|alt=Activity Indicator function|Activity Indicator]] | ||
Line 51: | Line 51: | ||
== Availability == | == Availability == | ||
This function is available from Exigo version 1.2. | This function is available from Exigo version 1.2. | ||
+ | |||
+ | [[Category:Exigo features]] | ||
+ | [[Category:Input Actions]] |
Revision as of 08:35, 17 August 2016
The "Activity Indicator" function can be assigned to any dak button on any access panel. This will designate the button as an indicator for activity in the selected zones within the priority range.
This function cannot be used on Control Inputs.
Contents
Settings
Parameters | |||||
---|---|---|---|---|---|
Destination | Select which zones to monitor for activity | ||||
Priority | Ignore activity which falls outside this priority range |
Use cases:
Case 1: Indicate alarm status
In this case the button is used to indicate that a specific alarm is activated. To obtain this we give the alarm a unique priority (21), and the "Activity indicator" is set to filter out all other activities.
Parameters | |||||
---|---|---|---|---|---|
Destination | None | ||||
Priority | 20-21 |
With the selected parameters the function will only check priority. If the alarm is the only one with priority 21, setting the priority field to a narrow selection of alarms between 20 and 21 means that no other activity will fulfill the required parameters, thus not triggering the Activity Indicator.
Case 2: Indicate activity in one zone
In this case the button is used to indicate that there is activity in zone 4 or zone 5.
Parameters | |||||
---|---|---|---|---|---|
Destination | Zone 4 and zone 5 | ||||
Priority | 1-100 |
The settings will in effect ignore the priority field and only filter on zones. If there is any activity in either zone 4 or zone 5 the activity led will then be triggered.
Availability
This function is available from Exigo version 1.2.