Difference between revisions of "SNMP recommended parameters"

From exigoWiki
Jump to navigation Jump to search
(Exigo 1.2.3.13)
(Exigo 1.2.3.13)
Line 31: Line 31:
 
|-
 
|-
 
| 1.3.6.1.4.1.26122.3.3.1 || fanTableCount || During startup || SSC + ENA ||  |
 
| 1.3.6.1.4.1.26122.3.3.1 || fanTableCount || During startup || SSC + ENA ||  |
 +
|-
 +
| 1.3.6.1.4.1.26122.3.3.2.1.2 || fanString || During startup || SSC + ENA ||  |
 
|-
 
|-
 
|}
 
|}

Revision as of 12:46, 12 June 2019

This article describes the SNMP parameters that are recommended to monitor.


Exigo 1.2.3.13

Exigo 1.2.3.13 is using SNMPv1.

OID Logical name Frequency Unit Priority
Memory usage MIB2 Memory usage Once every 60 second All
1.3.6.1.4.1.26122.3.1.4 infoAmplifierType During startup All
1.3.6.1.4.1.26122.3.1.1 infoPackageVersion During startup All
1.3.6.1.4.1.26122.3.2 temp
1.3.6.1.4.1.26122.3.2.1 tempTableCount
1.3.6.1.4.1.26122.3.2.2.1.2 tempSensorName During startup SSC + ENA
1.3.6.1.4.1.26122.3.2.2.1.7 tempAverageString During startup SSC + ENA
1.3.6.1.4.1.26122.3.2.2.1.8 tempAverageValue Twice every 60 second SSC + ENA
1.3.6.1.4.1.26122.3.3 fan
1.3.6.1.4.1.26122.3.3.1 fanTableCount During startup SSC + ENA
1.3.6.1.4.1.26122.3.3.2.1.2 fanString During startup SSC + ENA