Difference between revisions of "Activity Indicator"
(→Configuration) |
(→Configuration) |
||
Line 15: | Line 15: | ||
Select which zones to monitor for activity | Select which zones to monitor for activity | ||
− | '''Priority Range:''' Ignore activity that falls outside this priority range | + | '''<u>Priority Range:<u>'''<br> |
+ | Ignore activity that falls outside this priority range | ||
==Use Cases== | ==Use Cases== |
Revision as of 12:46, 2 May 2018
The Activity Indicator function can be assigned to any DAK button on any access panel. This will designate the button as an indicator for activity in the selected zones within the priority range.
This function cannot be used on Control Inputs.
Contents
Configuration
- Drag-and-drop Activity Indicator to:
Access Panel -> Programmable Keys -> p1-px -> press_action/release_action
Destination:
Select which zones to monitor for activity
Priority Range:
Ignore activity that falls outside this priority range
Use Cases
Case 1: Indicate Alarm Status
In this case, the button is used to indicate that a specific alarm is activated. To obtain this, we give the alarm a unique priority (21), and the Activity Indicator is set to filter out all other activities.
Parameters | |||||
---|---|---|---|---|---|
Destination | None | ||||
Priority Range | 20-21 |
With the selected parameters, the function will only check priority. If the alarm is the only one with priority 21, setting the priority field to a narrow range of alarms between 20 and 21 means that no other activity will fulfill the required parameters, thus not triggering the Activity Indicator.
Case 2: Indicate Activity in One Zone
In this case, the button is used to indicate that there is activity in Zone 4 or Zone 5.
Parameters | |||||
---|---|---|---|---|---|
Destination | Zone 4 and Zone 5 | ||||
Priority | 1-100 |
The settings will in effect ignore the priority field and only filter on zones. If there is any activity in either Zone 4 or Zone 5, the activity LED will then be triggered.
Availability
This function is available from Exigo version 1.2.