Difference between revisions of "Upgrade from 1.3.3.0 to 1.3.3.1"
Jump to navigation
Jump to search
(→Upgrade Precaution) |
(→Upgrade Precaution) |
||
Line 7: | Line 7: | ||
== Upgrade Precaution == | == Upgrade Precaution == | ||
− | When upgrading from Exigo 1.3.3.0 to 1.3.3.1 some precaution should be taken | + | When upgrading from Exigo 1.3.3.0 to 1.3.3.1 some precaution should be taken: <br> |
* In 1.3.3.0 systems where compensations for the low audio has been done, this must be removed. | * In 1.3.3.0 systems where compensations for the low audio has been done, this must be removed. | ||
** For example ENA amplifiers that have been adjusted to +2 dB should be reset to 0 dB. | ** For example ENA amplifiers that have been adjusted to +2 dB should be reset to 0 dB. | ||
+ | * All audio from the Alarm Generator must be checked to ensure correct audio level from the speakers. | ||
[[Category:Troubleshooting]] | [[Category:Troubleshooting]] |
Revision as of 13:46, 27 April 2018
An issue with the Alarm Generator have been observed on Exigo 1.3.3.0.
This has been fixed in Exigo 1.3.3.1.
Description
In Exigo 1.3.3.0 the audio generated from the Alarm Generator in the AMC-IP card was lower than it should be.
In Exigo 1.3.3.1 this has been corrected.
Upgrade Precaution
When upgrading from Exigo 1.3.3.0 to 1.3.3.1 some precaution should be taken:
- In 1.3.3.0 systems where compensations for the low audio has been done, this must be removed.
- For example ENA amplifiers that have been adjusted to +2 dB should be reset to 0 dB.
- All audio from the Alarm Generator must be checked to ensure correct audio level from the speakers.